Generalized breast density metrics
Open Access
- 19 December 2018
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (1) , 015006
Abstract
Mammograms represent data that can inform future risk of breast cancer. Data from two case-control study populations were analyzed. Population 1 included women (N = 180 age matched case-control pairs) with mammograms acquired with one indirect x-ray conversion mammography unit. Population 2 included women (N = 319 age matched case-control pairs) with mammograms acquired from 6 direct x-ray conversion units. The Fourier domain was decomposed into n concentric rings (radial spatial frequency bands). The power in each ring was summarized giving a set of measures. We investigated images in raw, for presentation (processed) and calibrated representations and made comparison with the percentage of breast density (BD) determined with the operator assisted Cumulus method. Breast cancer associations were evaluated with conditional logistic regression, adjusted for body mass index and ethnicity. Odds ratios (ORs), per standard deviation increase derived from the respective breast density distributions and 95% confidence intervals (CIs) were estimated. A measure from a lower radial frequency ring, corresponding 0.083–0.166 cycles mm−1 and BD had significant associations with risk in both populations. In Population 1, the Fourier measure produced significant associations in each representation: OR = 1.76 (1.33, 2.32) for raw; OR = 1.43 (1.09, 1.87) for processed; and OR = 1.68 (1.26, 2.25) for calibrated. BD also provided significant associations in Population 1: OR = 1.72 (1.27, 2.33). In Population 2, the Fourier measure produced significant associations for each representation as well: OR = 1.47 (1.19, 1.80) for raw; OR = 1.38 (1.15, 1.67) for processed; and OR = 1.42 (1.15, 1.75) for calibrated. BD provided significant associations in Population 2: OR = 1.43 (1.17, 1.76). Other coincident spectral regions were also predictive of case-control status. In sum, generalized breast density measures were significantly associated with breast cancer in both FFDM technologies.Keywords
Funding Information
- National Institutes of Health (R01CA114491, R01CA166269, U01CA200464)
This publication has 37 references indexed in Scilit:
- A comparison of calibration data from full field digital mammography units for breast density measurementsBioMedical Engineering OnLine, 2013
- Comparison of percent density from raw and processed full-field digital mammography dataBreast Cancer Research, 2013
- Mammographic density and breast cancer risk: current understanding and future prospectsBreast Cancer Research, 2011
- Full Field Digital Mammography and Breast DensityAcademic Radiology, 2011
- Volume of Mammographic Density and Risk of Breast CancerCancer Epidemiology, Biomarkers & Prevention, 2011
- Calibrated Measures for Breast Density EstimationAcademic Radiology, 2011
- A Quantitative Description of the Percentage of Breast Density Measurement Using Full-field Digital MammographyAcademic Radiology, 2011
- Effective radiation attenuation calibration for breast density: compression thickness influences and correctionBioMedical Engineering OnLine, 2010
- Texture Features from Mammographic Images and Risk of Breast CancerCancer Epidemiology, Biomarkers & Prevention, 2009
- Effective x-ray attenuation coefficient measurements from two full field digital mammography systems for data calibration applicationsBioMedical Engineering OnLine, 2008