Comparison of Five MR Sequences for the Detection of Acute Intracranial Hemorrhage
Authors:
- Catherine OppenheimCOCatherine Oppenheim
- Emmanuel TouzéETEmmanuel Touzé
- Danielle HernalsteenDHDanielle Hernalsteen
- André PeetersAPAndré Peeters
- Catherine LamyCLCatherine Lamy
- Jean-Louis MasJMJean-Louis Mas
- Jean-François MederJMJean-François Meder
- Guy CosnardGCGuy Cosnard
- 1 October 2005
- journal article
- research article
- Published by S. Karger AG in Cerebrovascular Diseases
- Vol. 20 (5) , 388-394
Abstract
Purpose: To evaluate the respective value of 5 MR sequences to distinguish between stroke patients with and without acute intracerebral hemorrhage (ICH). Methods: MR images obtained ≤6 h after stroke onset of 86 patients (43 ICH, 43 non-ICH) were reviewed by 3 observers who looked for signs of acute ICH on each image set [T1 and T2 gradient echo (GRE), FLAIR, T2-EPI and DWI], presented separately. Results: For the identification of ICH, intraobserver and interobserver concordance were at least ĸ = 0.95 for all sequences. Of all interpretations, 7 (0.4%) were erroneous, with sensitivity and specificity of FLAIR, T2-EPI and DWI reaching 100%; GRE sensitivity and specificity were 100% and 95–97.5%, respectively; T1 sensitivity and specificity were 97.3–100% and 97.4–100%, respectively. All 4 patients misclassified on one pulse sequence were correctly classified on all the other sequences. Conclusion: In the setting of acute stroke, each of the 5 studied sequences enables ICH and non-ICH patients to be distinguished with high sensitivity and specificity.Keywords
This publication has 12 references indexed in Scilit:
- Comparison of MRI and CT for Detection of Acute Intracerebral HemorrhageJAMA, 2004
- Contribution of Susceptibility-Weighted Imaging to Acute Stroke AssessmentStroke, 2004
- Stroke Magnetic Resonance Imaging Is Accurate in Hyperacute Intracerebral HemorrhageStroke, 2004
- Thrombolysis for Ischemic Stroke in Patients with Old Microbleeds on Pretreatment MRICerebrovascular Diseases, 2003
- B0 Images Obtained From Diffusion-Weighted Echo Planar Sequences for the Detection of Intracerebral BleedsJournal of Neuroimaging, 2003
- A characteristic feature of acute haematomas in the brain on echo-planar diffusion-weighted imagingNeuroradiology, 2002
- Hyperacute Stroke: Ultrafast MR Imaging to Triage Patients prior to TherapyRadiology, 1999
- A Standardized MRI Stroke ProtocolStroke, 1999
- Hemorrhagic and nonhemorrhagic stroke: diagnosis with diffusion-weighted and T2-weighted echo-planar MR imaging.Radiology, 1997
- Detection of Hyperacute Primary Intraparenchymal Hemorrhage by Magnetic Resonance ImagingStroke, 1996