Dosimetric effects of swelling or shrinking tissue during helical tomotherapy breast irradiation. A phantom study
Authors:
Open Access
- 8 July 2014
- journal article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 15 (4) , 382-391
Abstract
During radiation therapy of the female breast, the actual target volume compared to the planning target volume may change due to swelling or shrinking of the tissue. Under- or overdosage is to be expected, especially when performing IMRT or tomotherapy techniques. The objective of this study is to develop a model-based quantification of these dose effects, with a particular focus on the changes in the surface dose. A cylindrical phantom was used as an artificial surrogate of the human torso. By adding and removing Superflab layers of various thicknesses, both radial breast swelling and shrinking could be simulated. The effects on dose distribution were evaluated using film dosimetry. The results were compared to dose calculations. To estimate the true surface doses, we subtracted the influence of the film material on air measurements. During a swelling of 5, 10, and 15 mm, the planning target volume was consistently underdosed by 2%, 5%, and 7% of the prescribed dose, respectively. Swelling led to reduced dose values of up to 72%, 55%, and 50% at the outer edge of the actual target volume. The measured surface dose decreased successively from 31% to 23%. During shrinking, the dose in the planning target volume increased successively from 100% to 106%. The measured surface doses increased from 29% to 36%. The calculated dose values agreed with the measured values within error limits. During radiotherapy of the female breast, new planning appears to be essential for radial tissue swelling of 5 mm or more because of severe underdosing. Shrinking leads to moderate overdosing and an increased surface dose. In addition, caution is advised when removing bolus material with respect to the planned situation. PACS numbers: 87.53.Bn, 87.55.dk, 87.55.D-Keywords
This publication has 19 references indexed in Scilit:
- Intensity-modulated Radiotherapy in the Treatment of Breast CancerClinical Oncology, 2012
- Skin-sparing Helical Tomotherapy vs 3D-conformal Radiotherapy for Adjuvant Breast Radiotherapy: In Vivo Skin Dosimetry StudyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Effect of Breast Volume on Treatment Reproducibility on a Tomotherapy Unit in the Treatment of Breast CancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- Surface Dose in the Treatment of Breast Cancer with Helical TomotherapyStrahlentherapie und Onkologie, 2009
- Technique alternatives for breast radiation oncology: Conventional radiation therapy to tomotherapyJournal of Medical Physics, 2009
- SU‐GG‐T‐267: Evaluation of the Accuracy of TomoTherapy Dose Calculations for Shallow‐Depth PTVsMedical Physics, 2008
- Helical tomotherapy superficial dose measurementsMedical Physics, 2007
- An assessment of the use of skin flashes in helical tomotherapy using phantom and in-vivo dosimetryRadiotherapy and Oncology, 2007
- Superficial doses from serial tomotherapy deliveryMedical Physics, 2000
- The dosimetric consequences of inter-fractional patient movement on conventional and intensity-modulated breast radiotherapy treatmentsRadiotherapy and Oncology, 2000