This study investigates incorporating a partial copper wire mesh within a phase change material (PCM)-based battery pack to enhance heat dissipation. Nine series-connected 21700 lithium-ion cells (5000 mAh) were discharged at 1C to 3C (5–15 A) at an ambient temperature of 22 °C. A thermodynamic energy balance framework quantified heat generation, dissipation, and latent heat utilization. Experimental results indicate that integrating the copper mesh significantly improved heat dissipation, lowered peak cell temperatures, and reduced latent utilization. Compared to the baseline pure-PCM hybrid system, the mesh-PCM configuration decreased maximum mean cell temperatures by 3.7, 2.6, and 4.8 ± 0.6 °C at 1C, 2C, and 3C discharge rates, respectively, while increasing heat dissipation by 20%–40%. However, a specific thermophysical design trade-off was observed at the 3C rate, where the spatial temperature non-uniformity increased from 1.2 to 1.8 ± 0.1 °C. At moderate discharge rates (1C and 2C), the mesh-PCM system effectively managed heat without requiring macroscopic latent heat utilization, while at 3C, the bulk PCM melting fraction was reduced from 15.3% to 9.9%. This extends safe operational limits up to 3C. These findings highlight the partial mesh integration to enhance the performance of PCM-based battery thermal management system, offering a lightweight and effective upgrade for conventional pure-PCM hybrid cooling methods.
Funding Information
  • Natural Sciences and Engineering Research Council of Canada (RGPIN-2018-)
  • Natural Sciences and Engineering Research Council of Canada (05369)

This publication has 29 references indexed in Scilit: