Accuracy of a combined heart rate and motion sensor for assessing energy expenditure in free-living adults during a double-blind crossover caffeine trial using doubly labeled water as the reference method
- 2 April 2014
- journal article
- research article
- Published by Springer Nature in European Journal of Clinical Nutrition
- Vol. 69 (1) , 20-27
Abstract
Background/Objectives: A combined heart rate (HR) and motion sensor (Actiheart) has been proposed as an accurate method for assessing total energy expenditure (TEE) and physical activity energy expenditure (PAEE). However, the extent to which factors such as caffeine may affect the accuracy by which the estimated HR-related PAEE contribution will affect TEE and PAEE estimates is unknown. Therefore, we examined the validity of Actiheart in estimating TEE and PAEE in free-living adults under a caffeine trial compared with doubly labeled water (DLW) as reference criterion. Subjects/Methods: Using a double-blind crossover trial (Clinicaltrials.gov ID: #NCT01477294) with two conditions (4-day each with a 3-day-washout period), randomly ordered as caffeine (5 mg/kg per day) and placebo (malt-dextrine) intake, TEE was measured by DLW in 17 physically active men (20–38 years) who were non-caffeine users. In each condition, resting energy expenditure (REE) was assessed by indirect calorimetry and PAEE was calculated as (TEE−(REE+0.1 TEE)). Simultaneously, PAEE and TEE were estimated by Actiheart using an individual calibration (ACC+HRstep). Results: Under caffeine, ACC+HRstep explained 76 and 64% of TEE and PAEE from DLW, respectively; corresponding results for the placebo condition were 82 and 66%. No mean bias was found between ACC+HRstep and DLW for TEE (caffeine:-468 kJ per day; placebo:-407 kJ per day), although PAEE was slightly underestimated (caffeine:-856 kJ per day; placebo:-1147 kJ per day). Similar limits of agreement were observed in both conditions ranging from −2066 to 3002 and from −3488 to 1776 kJ per day for TEE and PAEE, respectively. Conclusions: Regardless of caffeine intake, the combined HR and motion sensor is valid for estimating free-living energy expenditure in a group of healthy men but is less accurate for an individual assessment.Keywords
This publication has 40 references indexed in Scilit:
- Accuracy and validity of a combined heart rate and motion sensor for the measurement of free-living physical activity energy expenditure in adults in CameroonInternational Journal of Epidemiology, 2010
- Caffeine (1, 3, 7‐trimethylxanthine) in Foods: A Comprehensive Review on Consumption, Functionality, Safety, and Regulatory MattersJournal of Food Science, 2010
- Assessing Validity and Reliability of Resting Metabolic Rate in Six Gas Analysis SystemsJournal of the American Dietetic Association, 2009
- Caffeine and sports performanceApplied Physiology, Nutrition, and Metabolism, 2008
- A new 2-regression model for the Actical accelerometerBritish Journal of Sports Medicine, 2007
- Reliability and validity of the combined heart rate and movement sensor ActiheartEuropean Journal of Clinical Nutrition, 2005
- Interindividual Variation in Posture Allocation: Possible Role in Human ObesityScience, 2005
- Caffeine ingestion and lower urinary tract symptoms in healthy volunteersNeurourology and Urodynamics, 2005
- Branched equation modeling of simultaneous accelerometry and heart rate monitoring improves estimate of directly measured physical activity energy expenditureJournal of Applied Physiology, 2004
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986