Objective To determine whether the Gyrus ACMI plasma kinetic bipolar device (Gyrus ACMI, Southborough, MA) improves pathologic specimen preservation and clinical outcomes compared to standard monopolar electrocautery. Patients and methods In our prospective study, 83 patients underwent monopolar or bipolar transurethral resection of bladder tumors between April 2006 and February 2007 at Memorial Sloan-Kettering Cancer Center. Dedicated genitourinary oncology pathologists blinded to resection type and assessed pathologic features including stage and grade, presence of muscularis propria, fragment size, presence and thickness of thermal artifacts within the specimen, layer of tissue most affected, severity of tissue distortion, and diagnostic impact of thermal artifacts. Clinical outcomes including, perforation, obturator reflex, need for muscle paralysis, a catheter, or admission, were recorded. Clinical and pathologic outcomes between resection modality were compared. Results There were no significant thermal artifacts in 9/38 (23.7 %) and 11/45 (24.4 %) monopolar and bipolar specimens, respectively. The layer of bladder tissue most affected by thermal artifacts was readable in 18/38 (47.4 %) monopolar and 27/45 (60.0 %) bipolar specimens. Tissue distortion from thermal artifacts led to areas within 11/38 (28.9 %) monopolar and 7/45 (15.6 %) bipolar specimens being unreadable. Ultimately, thermal artifacts caused moderate diagnostic difficulty in 2/38 (5.3 %) specimens of the monopolar group and severe diagnostic difficulty in 1/45 (2.2 %) bipolar specimens. Clinically, there was no major difference between resection methods. Conclusion Plasma kinetic bipolar equipment appears to cause less tissue distortion and has the potential to facilitate staging and grading of bladder tumors. No differences in clinical outcomes were appreciated between resection methods. If these results can be repeated in larger studies, the bipolar device represents a small advancement in transurethral resection.Keywords
This publication has 16 references indexed in Scilit:
- Comparison of Deep Biopsy Tissue Damage from Transurethral Resection of Bladder Tumors between Bipolar and Monopolar DevicesKorean Journal of Urology, 2011
- Bipolar energy for transurethral resection of bladder tumours at low‐power settings: initial experienceBJU International, 2010
- Bipolar Transurethral Resection in Saline (TURis ® ): Outcome and Complication Rates After the First 1000 CasesJournal of Endourology, 2009
- Use of Bipolar Energy for Transurethral Resection of Superficial Bladder Tumors: Long-Term ResultsJournal of Endourology, 2008
- Use of bipolar power source for transurethral resection of bladder tumor in patient with implanted pacemakerUrology, 2005
- Thermal Artifacts in Bladder Tumors Following Loop Endoresection: Electrovaporization v ElectrocauterizationJournal of Endourology, 2004
- Use of Bipolar Energy for Transurethral Resection of Bladder Tumors: Pathologic ConsiderationsJournal of Endourology, 2004
- Transurethral electrovaporization of bladder cancerUrology, 1996
- Controlled Bipolar High-Frequency Coagulation for Transurethral Application: A New Method for the Destruction of Urinary Bladder TumorsUrologia Internationalis, 1983
- Thigh Adductor Contraction During Transurethral Resection of Bladder Tumours: Evaluation of Inactive Electrode Placement and Obturator Nerve TopographyScandinavian Journal of Urology and Nephrology, 1981