OBJECTIVE: Digitally designed titanium plates are commonly used for the reconstruction of craniofacial defects, although implant exposure (referred to as failure) is one of the major complications. Metal hypersensitivities have been suggested as possible causes of implant failure of orthopedic, intravascular, gynecological, and dental devices, yet there has been no consensus on the requirement for allergy screening before cranioplasty.METHODS: In this study, the authors prospectively investigated the prevalence of metal hypersensitivity in patients for whom cranioplasty is planned and assess its relationship with titanium implant failure (exposure).RESULTS: Based on records from 207 included patients, 39.61% of patients showed hypersensitivity to at least one kind of metal. Approximately one-quarter (25.12%) of patients had multiple metal allergies. Co, Cd, and Zn were the 3 most frequently identified metal hypersensitivities. No allergy to titanium was detected in this study. The overall incidence of cranioplasty implant failure was 5.31% (11 of 207). Patients showing hypersensitivities to more than 3 kinds of metal had higher risks of titanium plate exposure.CONCLUSIONS: Based on their findings, the authors suggest that routine allergy screening be performed before titanium plate cranioplasty. For patients with hypersensitivities to more than 3 metals, alternative materials, such as polyetheretherketone, should be considered for cranioplasty.Keywords
This publication has 21 references indexed in Scilit:
- Outcomes following polyetheretherketone (PEEK) cranioplasty: Systematic review and meta-analysisJournal of Clinical Neuroscience, 2017
- Complications After In Vivo and Ex Vivo Autologous Bone Flap Storage for Cranioplasty: A Comparative Analysis of the LiteratureWorld Neurosurgery, 2016
- Custom-made titanium cranioplasty: early and late complications of 151 cranioplasties and review of the literatureInternational Journal of Oral and Maxillofacial Surgery, 2015
- Comparison of Polyetheretherketone and Titanium Cranioplasty after Decompressive CraniectomyWorld Neurosurgery, 2015
- Clinical Outcomes in CranioplastyPlastic and Reconstructive Surgery, 2014
- Patch Testers’ Opinions Regarding Diagnostic Criteria for Metal Hypersensitivity Reactions to Metallic ImplantsDermatitis®, 2013
- The Role of Patch Testing in the Evaluation of Orthopedic Implant-Related Adverse Effects: Current Evidence Does Not Support Broad UseDermatitis®, 2013
- Cognitive improvement after cranioplasty: A possible volume transmission-related effectActa Neurochirurgica, 2012
- Neurocognitive Assessment Before and after CranioplastyActa Neurochirurgica, 2002
- In vitro T‐cell responses to β‐lactam drugs in immediate and nonimmediate allergic reactionsAllergy, 2001