Front-End ASIC for High Resolution X-Ray Spectrometers
Authors:
- Jessica A. GaskinJGJessica A. Gaskin
- Brian D. RamseyBRBrian D. Ramsey
- Giovanni AnelliGAGiovanni Anelli
- 17 June 2008
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 55 (3) , 1604-1609
Abstract
We present an application specific integrated circuit (ASIC) for high-resolution X-ray spectrometers. The ASIC is designed to read out signals from a pixelated silicon drift detector (SDD). Each hexagonal pixel has an area of 15 mm2 and an anode capacitance of less than 100 fF. There is no integrated Field Effect transistor (FET) in the pixel, rather, the readout is done by wire-bonding the anodes to the inputs of the ASIC. The ASIC provides 14 channels of low-noise charge amplification, high-order shaping with baseline stabilization, and peak detection with analog memory. The readout is sparse and based on low voltage differential signaling. An interposer provides all the interconnections required to bias and operate the system. The channel dissipates 1.6 mW. The complete 14-pixel unit covers an area of 210 mm2, dissipates 12 mW cm-2, and can be tiled to cover an arbitrarily large detection area. We measured a preliminary resolution of 172 eV at -35 degC on the 6 keV peak of a 55Fe source.Keywords
This publication has 26 references indexed in Scilit:
- Silicon drift detectors with enlarged sensitive areasX-Ray Spectrometry, 2004
- C05 Silicon Drift Detectors for High Resolution, High Count Rate X-ray Spectroscopy at Room TemperaturePowder Diffraction, 2003
- Charge-sensitive preamplifier with continuous reset by means of the gate-to-drain current of the JFET integrated on the detectorIEEE Transactions on Nuclear Science, 2002
- A monolithic array of silicon, drift detectors for high-resolution gamma-ray imagingIEEE Transactions on Nuclear Science, 2002
- A CMOS fully compensated continuous reset systemIEEE Transactions on Nuclear Science, 2000
- A CMOS baseline holder (BLH) for readout ASICsIEEE Transactions on Nuclear Science, 2000
- Spectral response of multi-element silicon X-ray detectorsIEEE Transactions on Nuclear Science, 1998
- Spiral silicon drift detectorsIEEE Transactions on Nuclear Science, 1989
- Semiconductor drift chamber — An application of a novel charge transport schemeNuclear Instruments and Methods in Physics Research, 1984
- Direct synthesis of the Gaussian filter for nuclear pulse amplifiersNuclear Instruments and Methods, 1976