Effect of Concrete Environment on the Corrosion Performance of Epoxy-Coated Reinforcing Steel

Authors:

Abstract
Corrosion of marine bridge substructure using concrete with epoxy-coated reinforcing steel has been observed in Florida Keys bridges. The mechanism of coating disbondment has been investigated by exposing regular production epoxy-coated rebars to liquid solutions of calcium hydroxide, sodium chloride, and calcium hydroxide with sodium chloride. Test exposures were conducted with freely corroding specimens and also under potentiostatic control with cathodic and anodic polarization. The calcium hydroxide-only solutions produced no adverse effects at any of the exposure conditions. The sodium chloride tests produced significant disbondment at the open circuit potential and under cathodic polarization. The mixed calcium hydroxide-sodium chloride solutions caused disbondment and corrosion under anodic polarization that reproduce much of the corrosion morphology observed in the field. It is tentatively proposed that corrosion in the field takes place at the anode of macrocells which result from the geometrical and environmental configuration of the substructure. The corrosion is aggravated by rebar fabrication and possibly by weathering of the rebar prior to construction.