Gait Parameters Can Be Derived Reliably and Validly from Augmented Reality Glasses in People with Parkinson’s Disease Performing 10-m Walk Tests at Comfortable and Fast Speeds
Open Access
Abstract
The 10-m walk test (10MWT) is a stopwatch-based clinical mobility assessment. To better understand mobility limitations, 10MWT test completion times may be complemented with gait parameters like step length. State-of-the-art augmented reality (AR) glasses can potentially do this given their unique 3D-positional data from which gait parameters may be derived. We examined the test-retest reliability, concurrent validity, and face validity of gait parameters derived from AR glasses during a 10MWT in 20 people with Parkinson’s disease, performed at self-selected comfortable and fast-but-safe walking speeds. AR-derived 10MWT completion times and gait parameters (mean step length, cadence, and maximal gait speed) were compared across repetitions and with lab-based (Interactive Walkway) and clinical (stopwatch) reference systems. Good-to-excellent test-retest reliability statistics were observed for test completion times and gait parameters for all systems and conditions alike. Concurrent validity was demonstrated between AR, lab-based, and clinical references for test completion times (good-to-excellent agreement: ICC > 0.879) and gait parameters (excellent agreement: ICC > 0.942). Face validity was confirmed by significant differences in test completion times and gait parameters between speed conditions in a-priori expected directions. These findings support the conclusion that gait parameters can be derived reliably and validly from AR glasses in people with Parkinson’s disease.Keywords
Funding Information
- European Union
- Horizon Europe grant for project NavigAIt
- European Innovation Council
- United Kingdom Research and Innovation (UKRI)
This publication has 48 references indexed in Scilit:
- An augmented reality dual-task intervention improves postural stability in individuals with Parkinson’s diseaseGait & Posture, 2024
- Holographic Hintways: A systems feasibility and usability study of augmented reality cueing for gait adaptationGait & Posture, 2023
- Visual SLAM algorithms and their application for AR, mapping, localization and wayfindingArray, 2022
- Are cost-effective technologies feasible to measure gait in older adults? A systematic review of evidence-based literatureArchives of Gerontology and Geriatrics, 2020
- The use of wearable devices for walking and running gait analysis outside of the lab: A systematic reviewGait & Posture, 2018
- Walking-adaptability assessments with the Interactive Walkway: Between-systems agreement and sensitivity to task and subject variationsGait & Posture, 2017
- Measurement instruments to assess posture, gait, and balance in Parkinson's disease: Critique and recommendationsMovement Disorders, 2016
- Quantitative wearable sensors for objective assessment of Parkinson's diseaseMovement Disorders, 2013
- Reliability of the new freezing of gait questionnaire: Agreement between patients with Parkinson's disease and their carersGait & Posture, 2009
- Movement Disorder Society‐sponsored revision of the Unified Parkinson's Disease Rating Scale (MDS‐UPDRS): Scale presentation and clinimetric testing resultsMovement Disorders, 2008