Marker-Free Tracking for Motion Artifact Compensation and Deformation Measurements in Optical Mapping Videos of Contracting Hearts
Authors:
Open Access
- 2 November 2018
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 9, 1483
Abstract
Optical mapping is a high-resolution fluorescence imaging technique, which provides highly detailed visualizations of the electrophysiological wave phenomena, which trigger the beating of the heart. Recent advancements in optical mapping have demonstrated that the technique can now be performed with moving and contracting hearts and that motion and motion artifacts, once a major limitation, can now be overcome by numerically tracking and stabilizing the heart's motion. As a result, the optical measurement of electrical activity can be obtained from the moving heart surface in a co-moving frame of reference and motion artifacts can be reduced substantially. The aim of this study is to assess and validate the performance of a 2D marker-free motion tracking algorithm, which tracks motion and non-rigid deformations in video images. Because the tracking algorithm does not require markers to be attached to the tissue, it is necessary to verify that it accurately tracks the displacements of the cardiac tissue surface, which not only contracts and deforms, but also fluoresces and exhibits spatio-temporal physiology-related intensity changes. We used computer simulations to generate synthetic optical mapping videos, which show the contracting and fluorescing ventricular heart surface. The synthetic data reproduces experimental data as closely as possible and shows electrical waves propagating across the deforming tissue surface, as seen during voltage-sensitive imaging. We then tested the motion tracking and motion-stabilization algorithm on the synthetic as well as on experimental data. The motion tracking and motion-stabilization algorithm decreases motion artifacts approximately by 80% and achieves sub-pixel precision when tracking motion of 1–10 pixels (in a video image with 100 by 100 pixels), effectively inhibiting motion such that little residual motion remains after tracking and motion-stabilization. To demonstrate the performance of the algorithm, we present optical maps with a substantial reduction in motion artifacts showing action potential waves propagating across the moving and strongly deforming ventricular heart surface. The tracking algorithm reliably tracks motion if the tissue surface is illuminated homogeneously and shows sufficient contrast or texture which can be tracked or if the contrast is artificially or numerically enhanced. In this study, we also show how a reduction in dissociation-related motion artifacts can be quantified and linked to tracking precision. Our results can be used to advance optical mapping techniques, enabling them to image contracting hearts, with the ultimate goal of studying the mutual coupling of electrical and mechanical phenomena in healthy and diseased hearts.Keywords
This publication has 20 references indexed in Scilit:
- Optical Imaging of Voltage and Calcium in Cardiac Cells & TissuesCirculation Research, 2012
- Simultaneous optical mapping of transmembrane potential and wall motion in isolated, perfused whole heartsJournal of Biomedical Optics, 2011
- A Discrete Model to Study Reaction-Diffusion-Mechanics SystemsPLOS ONE, 2011
- Structural Heterogeneity in the Ventricular Wall Plays a Significant Role in the Initiation of Stretch-Induced Arrhythmias in Perfused Rabbit Right Ventricular Tissues and Whole Heart PreparationsCirculation Research, 2010
- Application of blebbistatin as an excitation–contraction uncoupler for electrophysiologic study of rat and rabbit heartsHeart Rhythm, 2007
- Correction of Motion Artifact in Cardiac Optical Mapping Using Image RegistrationIEEE Transactions on Biomedical Engineering, 2005
- Correction of motion artifact in transmembrane voltage-sensitive fluorescent dye emission in heartsAmerican Journal of Physiology-Heart and Circulatory Physiology, 2004
- Electromechanical model of excitable tissue to study reentrant cardiac arrhythmiasProgress in Biophysics and Molecular Biology, 2004
- Cardiac excitation–contraction couplingNature, 2002
- A simple two-variable model of cardiac excitationChaos, Solitons & Fractals, 1996