Abstract
A simplified clean-up procedure was developed in combination with gas chromatography-tandem mass spectrometry (GC-MS/MS) for the determination of polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) in adipose tissue. Clean-up was performed by the successive application of a Mega Bond Elut® silica column and a Bond Elut® PCB column. Validation of the method was conducted according to European Union Commission Decision 2002/657/EC. In order to evaluate the applicability of the method, 44 horse fat samples were analysed. The total PCB concentration (sum of PCBs 28, 52, 101, 118, 138, 153 and 180) ranged from 5.35 to 140 ng g–1 lipid weight. The total PBDE concentration (sum of BDEs 28, 47, 99, 100, 153, 154 and 183) ranged from below the decision limit to 6.34 ng g–1 lipid weight.