A study on plasma edge boundary in ergodic layer of LHD based on radial profile measurement of impurity line emissions
Authors:
- 1 August 2011
- journal article
- conference paper
- Published by AIP Publishing in Physics of Plasmas
- Vol. 18 (8) , 082511
Abstract
Vertical profiles of edge impurity emissions have been measured in upper half region of elliptical plasmas at horizontally elongated plasma cross section in large helical device (LHD). The vertical profiles near upper O-point located just below helical coil are analyzed to study the plasma edge boundary of the ergodic layer consisting of stochastic magnetic field lines with connection lengths of 30 ≤ Lc ≤ 2000 m. As a result, C3+ ion emitting CIV spectrum is identified as the ion existing in the farthest edge of the ergodic layer. The peak position of CIV (312.4 Å: 1s23p 2P1/2,3/2-1s22s 2S1/2) vertical profile does not change at all in a wide temperature range of 150 ≤ Te(ρ = 1) ≤ 400 eV, whereas it moves inside the ergodic layer when Te(ρ = 1) is reduced below a threshold temperature, e.g., 130 eV at Rax = 3.75 m configuration. It is found that the C3+ ion exists at the boundary between ergodic layer and open magnetic filed layer at which the Lc distributes in lengths of 5 to 30 m. The result indicates that the edge boundary near the O-point in LHD is determined by a starting point of the open filed layer, where a tokamak-like steeper edge temperature gradient is formed, although the edge boundary is quite obscure at the X-point region. Any plasma does not exist between the edge boundary and the vacuum vessel. The CIV profile at the O-point is simulated using a three-dimensional edge transport code of EMC3-EIRENE in which the magnetic field structure in vacuum is used for the ergodic layer. A clear discrepancy of 8 mm is found in the peak positions of CIV between measurement and simulation for magnetic configurations with thick ergodic layer, i.e., Rax =3.90 m, while only a small discrepancy of 3 mm is observed for those with relatively thin ergodic layer, i.e., Rax = 3.75 m. It suggests that the discrepancy is caused by a modification of the magnetic filed due to the presence of plasma pressure.Keywords
This publication has 31 references indexed in Scilit:
- Improvements of data quality of the LHD Thomson scattering diagnostics in high-temperature plasma experimentsReview of Scientific Instruments, 2010
- H-mode-like transition and ELM-like bursts in LHD with thick ergodic layerNuclear Fusion, 2007
- Plasma shape control on the National Spherical Torus Experiment (NSTX) using real-time equilibrium reconstructionNuclear Fusion, 2005
- Confinement and gas fueling in LHD limiter dischargesJournal of Nuclear Materials, 2003
- Ion temperature measurement using an ion sensitive probe in the LHD divertor plasmaJournal of Nuclear Materials, 2003
- Ergodic edge region of large helical deviceJournal of Nuclear Materials, 2003
- Semi-Empirical Approach to Determine the Plasma Boundary of Toroidal Helical Equilibria in LHDJournal of Plasma and Fusion Research, 2003
- Real time equilibrium reconstruction for tokamak discharge controlNuclear Fusion, 1998
- Plasma shape and position control in highly elongated tokamaksNuclear Fusion, 1990
- Three-dimensional free boundary calculations using a spectral Green's function methodComputer Physics Communications, 1986