Tolerability and Functionality of a Wireless 24-Hour Ocular Telemetry Sensor in African American Glaucoma Patients
- 1 February 2019
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 28 (2) , 119-124
Abstract
Purpose: The purpose of the study was to evaluate the tolerability and functionality of a wireless ocular telemetry sensor in African American patients with glaucoma. Materials and Methods: In this prospective, observational cohort study, 20 African American patients with primary open angle glaucoma (POAG) were evaluated at the University of Colorado Eye Center. Before lens placement, patients recorded ocular comfort and underwent a baseline eye exam. Following the exam, patients were fitted with a SENSIMED Triggerfish contact lens sensor and data recording device. Patients were sent home and instructed to record their activities in a journal and return in 24 hours. Repeat exams were performed at various time points in clinic before and after lens removal. Results: All 20 patients retained the lens for the 24-hour study period. The patient reported comfort was excellent, with a nadir of mean recorded comfort of 7.05/10. Significant clinical changes were noted in lid/conjunctival erythema, BCVA, refraction, and pachymetry over the course of lens wear. The majority of these changes were improved or resolved by 1 hour after lens removal. Voltage output was significantly greater nocturnally than diurnally (184.79 mV and 71.48 mV, respectively; P<0.0001). There was no significant change in signal variability or slope over the entire duration of the sleep/wake period based on sleep. Conclusions: The wireless ocular sensor is well tolerated over a 24-hour period in African American patients with POAG despite transient changes in visual acuity and conjunctival erythema. Clinically usable 24-hour profiles were generated for all patients, with voltage output increasing significantly during periods of sleep.Keywords
This publication has 28 references indexed in Scilit:
- The 24-Hour Effects of Brinzolamide/Brimonidine Fixed Combination and Timolol on Intraocular Pressure and Ocular Perfusion PressureJournal of Ocular Pharmacology and Therapeutics, 2017
- Systematic Review of Current Devices for 24-h Intraocular Pressure MonitoringAdvances in Therapy, 2016
- 24-Hour Intraocular Pressure Rhythm in Young Healthy Subjects Evaluated With Continuous Monitoring Using a Contact Lens SensorJAMA Ophthalmology, 2013
- Risk Factors and Open-angle Glaucoma: Classification and ApplicationJournal of Glaucoma, 2007
- 24-Hour Monitoring of Intraocular Pressure in Glaucoma Management: A Retrospective ReviewJournal of Glaucoma, 2003
- Twenty-four-Hour Intraocular Pressure Pattern Associated with Early Glaucomatous ChangesInvestigative Ophthalmology & Visual Science, 2003
- Reduction of Intraocular Pressure and Glaucoma ProgressionArchives of Ophthalmology (1950), 2002
- Large Diurnal Fluctuations in Intraocular Pressure Are an Independent Risk Factor in Patients With GlaucomaJournal of Glaucoma, 2000
- Relationship Between Intraocular Pressure and Primary Open Angle Glaucoma Among White and Black AmericansArchives of Ophthalmology (1950), 1991
- Racial Variations in the Prevalence of Primary Open-angle GlaucomaJAMA, 1991