A cadaveric temporal bone study of the anatomical landmarks for middle turn cochleostomy
- 23 January 2023
- journal article
- research article
- Published by Cambridge University Press (CUP) in The Journal of Laryngology & Otology
- Vol. 137 (7) , 769-774
Abstract
Objective: This study aimed to determine anatomical landmarks for accurate and safe middle turn cochleostomy on cadaveric temporal bones.Methods: In 17 cadaveric wet adult temporal bones, cortical mastoidectomy was performed, followed by extended posterior tympanotomy through which a middle turn opening was created anterior to the stapes footplate. Micro-measurements of various lengths were taken from the cochleostomy to normal middle-ear anatomical landmarks using a digital microscope.Results: The mean length from the middle turn cochleostomy to the processus cochleariformis was 1.8 ± 0.3 mm and to the tympanic segment of the facial nerve was 2.2 ± 0.3 mm. The mean shortest length from the oval window to the osseous spiral lamina was 2.4 ± 0.3 mm and to the internal carotid artery was 5.0 ± 0.6 mm. The mean shortest length from the round window to the internal carotid artery was 4.3 ± 0.6 mm.Conclusion: A middle turn cochleostomy can be safely drilled by using the measured lengths in difficult cases.Keywords
Funding Information
- Christian Medical College, Vellore
This publication has 13 references indexed in Scilit:
- A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability ResearchJournal of Chiropractic Medicine, 2016
- The Anatomical Orientation of the Middle Turn of the CochleaOtology & Neurotology, 2015
- Beyond the Middle EarOtolaryngologic Clinics of North America, 2013
- Anatomy of the Middle‐Turn CochleostomyThe Laryngoscope, 2008
- Role of Electrode Placement as a Contributor to Variability in Cochlear Implant OutcomesOtology & Neurotology, 2008
- Does the surgical approach in cochlear implantation influence the occurrence of postoperative vertigo?Otolaryngology–Head and Neck Surgery, 2008
- Quality Control After Insertion of the Nucleus Contour and Contour Advance Electrode in AdultsEar & Hearing, 2007
- The Results in Patients Implanted with the Nucleus Double Array Cochlear Implant: Pitch Discrimination and Auditory PerformanceEar & Hearing, 2002
- The Nucleus Double Array Cochlear Implant: A New Concept for the Obliterated CochleaOtology & Neurotology, 2001
- Labyrinthitis ossificans: Histopathologic consideration for cochlear implantationOtolaryngology–Head and Neck Surgery, 1991