The Impact of Myopia Control Spectacle Lens Designs on Visual Function
Open Access
- 5 March 2026
- journal article
- research article
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 46 (1) , 49-59
Abstract
Purpose: To profile the immediate effect of defocus-modulating and contrast-modulating myopia control spectacle lens interventions on visual function. Methods: Healthy myopic (mean spherical equivalent (MSE) −4.25 to −0.50 D) young adults, corrected with contact lenses, wore diffusion optics technology (DOT), defocus incorporated multiple segments (DIMS), highly aspherical lenslets (HAL) and standard single vision (SV) plano trial spectacle lenses, in a prospective, single-visit, double-blind, four-way randomised crossover study. Distance and near high- and low-contrast visual acuity (VA), contrast sensitivity, reading performance, accommodative facility, visual search task and accommodative accuracy were assessed foveally through the central zone (CZ) and/or peripheral zone (PZ) of the lenses. Results: Twenty participants (16 female) were recruited, with a mean (±SD) age of 22.4 (±2.72) years and MSE −2.21 (±1.10) D. VAs through the PZ differed significantly between myopia control lenses and SV, with the HAL and DIMS exhibiting lower VA across all testing conditions (all p p 0.05), whereas DIMS exhibited worse near acuity threshold and critical print size ( p 0.05) or visual search duration (CZ: p = 0.68; PZ: p = 0.35). Accommodative response was similar across lenses (all p >0.05); however, SV had lower variability at distance through the PZ than DOT, HAL and DIMS ( p <0.001). Conclusion: All three myopia control lenses exhibited visual performance comparable to standard SV lenses through the CZ. Clinicians should note differences in visual performance, especially VA and reading speed through the lens periphery and their relative testing.Keywords
This publication has 68 references indexed in Scilit:
- Statistical guidelines for clinical studies of human visionOphthalmic and Physiological Optics, 2011
- Effect of near adds on the variability of accommodative response in myopic childrenOphthalmic and Physiological Optics, 2011
- Clinical evaluation of the Grand Seiko Auto Ref/Keratometer WAM-5500Ophthalmic and Physiological Optics, 2010
- Accommodation response and visual discomfortOphthalmic and Physiological Optics, 2009
- Adaptive changes in visual cortex following prolonged contrast reductionJournal of Vision, 2009
- Technical Note: Effect of contact lenses on measurement of the accommodation microfluctuationsOphthalmic and Physiological Optics, 2007
- Spectral filters can improve reading and visual search in patients with multiple sclerosisJournal of Neurology, 2007
- Modeling logMAR Visual Acuity Scores: Effects of Termination Rules and Alternative Forced-Choice OptionsOptometry and Vision Science, 2001
- Continuous recording of accommodation and pupil size using the Shin‐Nippon SRW‐5000 autorefractorOphthalmic and Physiological Optics, 2001
- Repeatability of Visual Acuity MeasurementOptometry and Vision Science, 1998