Experimental Evaluation of Immediate Recanalization Effect and Recanalization Efficacy of a New Thrombus Retriever for Acute Stroke Treatment In Vivo
Open Access
- 26 July 2012
- journal article
- research article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 34 (1) , 153-158
Abstract
BACKGROUND AND PURPOSE: Currently, several new stent retriever devices for acute stroke treatment are under development and early clinical evaluation. Preclinical testing under standardized conditions is an important first step to evaluate the technical performance and potential of these devices. The aim of this study was to evaluate the immediate recanalization effect, recanalization efficacy, thrombus-device interaction, and safety of a new stent retriever intended for thrombectomy in patients with acute stroke. MATERIAL AND METHODS: The pREset thrombectomy device (4 × 20 mm) was evaluated in 16 vessel occlusions in an established swine model. Radiopaque thrombi (10-mm length) were used for visualization of thrombus-device interaction during application and retrieval. Flow-restoration effect immediately after deployment and after 5-minute embedding time before retrieval, recanalization rate after retrieval, thromboembolic events, and complications were assessed. High-resolution FPCT was performed to illustrate thrombus-device interaction during the embedding time. RESULTS: Immediate flow restoration was achieved in 75% of occlusions. An increase or stable percentage of recanalizations during embedding time before retrieval was seen in 56.3%; a decrease, in 12.5%; reocclusion of a previously recanalized vessel, in 18.8%; and no recanalization effect at all, in 12.5%. Complete recanalization (TICI 3) after retrieval was achieved in 93.8%; partial recanalization (TICI 2b), in 6.2%. No distal thromboembolic events were observed. High-resolution FPCT illustrated entrapment of the thrombus between the stent struts and compression against the contralateral vessel wall, leading to partial flow restoration. During retrieval, the thrombus was retained in a straight position within the stent struts. CONCLUSIONS: In this experimental study, the pREset thrombus retriever showed a high recanalization rate in vivo. High-resolution FPCT allows detailed illustration of the thrombus-device interaction during embedding time and is advocated as an add-on tool to the animal model used in this study.Keywords
This publication has 16 references indexed in Scilit:
- Mechanical Thrombectomy in Acute Embolic StrokeStroke, 2011
- Rescue, Combined, and Stand-Alone Thrombectomy in the Management of Large Vessel Occlusion Stroke Using the Solitaire Device: A Prospective 50-Patient Single-Center StudyStroke, 2011
- Impact of Retrievable Stents on Acute Ischemic Stroke TreatmentAmerican Journal of Neuroradiology, 2011
- Stent-Assisted Mechanical Recanalization for Treatment of Acute Intracerebral Artery OcclusionsStroke, 2010
- In Vivo Evaluation of the First Dedicated Combined Flow-Restoration and Mechanical Thrombectomy Device in a Swine Model of Acute Vessel OcclusionAmerican Journal of Neuroradiology, 2010
- Mechanical Thrombectomy With the Solitaire AB Device in Large Artery Occlusions of the Anterior CirculationStroke, 2010
- In Vivo Evaluation of the Phenox CRC Mechanical Thrombectomy Device in a Swine Model of Acute Vessel OcclusionAmerican Journal of Neuroradiology, 2009
- Percutaneous Transluminal Angioplasty and Stent Placement in Acute Vessel Occlusion: Evaluation of New Methods for Interventional Stroke TreatmentAmerican Journal of Neuroradiology, 2009
- Mechanical Thromboembolectomy for Acute Ischemic StrokeStroke, 2008
- Trial Design and Reporting Standards for Intra-Arterial Cerebral Thrombolysis for Acute Ischemic StrokeStroke, 2003