Computer Model Analysis of the Swanson and Sutter Metacarpophalangeal Joint Implants
Authors:
- 1 April 2000
- journal article
- research article
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 25 (2) , 212-220
Abstract
A representative model which mimics the behaviour of Silastic® finger metacarpophalangeal joint implants was constructed using a finite element software package. The modelled implants were moved through a range of flexion, lateral deviation and a combination of both. Pistoning of both implants stems occurred within the modelled medullary cavities. For equivalent flexion angles, the Sutter implant produced a higher stress field than the Swanson implant, and the field was positioned at the central hinge mechanism. In both implants, lateral deviation increased the internal stress concentrations more than when pure flexion was applied. Overall the Swanson style of implant had lower stress magnitudes than the Sutter implant, and it is predicted that the Sutter implant will be more likely to fail than the Swanson. The failure mode for the Sutter implant would be at the central hinge region. The Swanson implant is likely to fail at the central hinge-stem interface regions.Keywords
This publication has 13 references indexed in Scilit:
- High implant fracture incidence with sutter silicone metacarpophalangeal joint arthroplastyThe Journal of Hand Surgery, 1996
- Numerical solution of the contact problem. Application to a simple model of the human hip jointJournal of Computational and Applied Mathematics, 1995
- Effect of implant material properties on the performance of a hip joint replacementJournal of Medical Engineering & Technology, 1994
- Arthroplasty of the metacarpophalangeal joints with use of silicone-rubber implants in patients who have rheumatoid arthritis. Long-term results.Journal of Bone and Joint Surgery, 1993
- Stress analysis of a flexible one-piece type first metatarsophalangeal joint implantJournal of the American Podiatric Medical Association, 1993
- A survey of finite element analysis in orthopedic biomechanics: The first decadeJournal of Biomechanics, 1983
- Biomechanical evaluation of metacarpophalangeal joint prosthesis designsThe Journal of Hand Surgery, 1979
- Laboratory Evaluation of a Metal-plastic Type of Metacarpophalangeal Joint ProsthesisClinical Orthopaedics and Related Research, 1975
- Metacarpophalangeal Joint Implants:I. Roentgenographic Study on the Silastic® Finger Joint Implant, Swanson DesignScandinavian Journal of Plastic and Reconstructive Surgery, 1975
- Silicone Rubber Implants for Replacement of Arthritic or Destroyed Joints in the HandSurgical Clinics of North America, 1968