Disposable Voltammetric Immunosensor for Determination and Quantification of Biomarker CA 15-3 in Biological Specimens
Open Access
Abstract
A disposable voltammetric immunosensor was developed to measure breast cancer biomarker 15-3 (CA 15-3) in human saliva and serum samples. Screen-printed paper-based electrodes (f-SPE) previously fabricated by our research group using homemade conductive inks were used as transducers, which were later modified only with gold nanoparticles to immobilize anti-CA 15-3 antibodies. The sensor was operated using antigen–antibody interactions in conjunction with a redox species (ferrocyanide potassium) for the indirect determination of the CA 15-3 antigen. The device characterization involved atomic force microscopy (AFM) and electrochemical analysis. Optimization of the construction and response of the immunosensor was achieved at incubation times of 6 h for anti-CA 15-3, 1 h for bovine serum albumin, and 1 h for interaction with CA 15-3. The sensor displays a linear range between 2 and 16 U/mL, with a sensitivity of 0.012 μA/U mL−1, a limit of detection (LOD) of 0.56 U/mL, and a limit of quantification (LOQ) of 1.88 U/mL. The interfering substances minimally affected the signal, with 4.94% response variation, and the reproducibility of the immunosensor demonstrated a relative standard deviation (RSD) of 5.65%. The sensor successfully determined the CA 15-3 concentration in human serum and saliva, demonstrating its potential for clinical analysis.Keywords
Funding Information
- Conselho Nacional de Desenvolvimento Científico e Tecnológico—CNPq (465571/2014-0, 404210/2021-0, 305360/2022-1, APQ-00207-21, APQ-00679-22)
- Fundação de Amparo à Pesquisa do Estado de Minas Gerais—FAPEMIG (465571/2014-0, 404210/2021-0, 305360/2022-1, APQ-00207-21, APQ-00679-22)
This publication has 42 references indexed in Scilit:
- Assessing Clinical Significance of Serum CA15-3 and Carcinoembryonic Antigen (CEA) Levels in Breast Cancer Patients: A Meta-AnalysisMedical Science Monitor, 2016
- Single-domain antibody based thermally stable electrochemical immunosensorBiosensors and Bioelectronics, 2016
- Clinical significance of serum CA15-3 as a prognostic parameter during follow-up periods in patients with breast cancerAnnals of Surgical Treatment and Research, 2016
- Antibody-Conjugated Gold Nanoparticle-Based Immunosensor for Ultra-Sensitive Detection of Troponin-TSLAS Technology, 2014
- Electrochemical co-reduction synthesis of Au/ferrocene–graphene nanocomposites and their application in an electrochemical immunosensor of a breast cancer biomarkerAnalytical Methods, 2014
- Significant Correlation between Salivary and Serum Ca 15-3 in Healthy Women and Breast Cancer PatientsAsian Pacific Journal of Cancer Prevention, 2014
- Lectin-based optical sensing for quantitative analysis of cancer antigen CA15-3 as a breast cancer markerSensors and Actuators B: Chemical, 2013
- Electrochemical immunosensor with N-doped graphene-modified electrode for label-free detection of the breast cancer biomarker CA 15-3Biosensors and Bioelectronics, 2013
- Detection of Circulating Anti-Mucin 1 (MUC1) Antibodies in Breast Tumor Patients by Indirect Enzyme-Linked Immunosorbent Assay Using a Recombinant MUC1 Protein Containing Six Tandem Repeats and Expressed in Escherichia coliClinical and Vaccine Immunology, 2010
- Mucin structure, aggregation, physiological functions and biomedical applicationsCurrent Opinion in Colloid & Interface Science, 2006