Dual-energy fluorescent x-ray computed tomography system with a pinhole design: Use of K-edge discontinuity for scatter correction
Authors:
Open Access
- 8 March 2017
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , srep44143
Abstract
We propose a pinhole-based fluorescent x-ray computed tomography (p-FXCT) system with a 2-D detector and volumetric beam that can suppress the quality deterioration caused by scatter components. In the corresponding p-FXCT technique, projections are acquired at individual incident energies just above and below the K-edge of the imaged trace element; then, reconstruction is performed based on the two sets of projections using a maximum likelihood expectation maximization algorithm that incorporates the scatter components. We constructed a p-FXCT imaging system and performed a preliminary experiment using a physical phantom and an I imaging agent. The proposed dual-energy p-FXCT improved the contrast-to-noise ratio by a factor of more than 2.5 compared to that attainable using mono-energetic p-FXCT for a 0.3 mg/ml I solution. We also imaged an excised rat’s liver infused with a Ba contrast agent to demonstrate the feasibility of imaging a biological sample.Keywords
This publication has 27 references indexed in Scilit:
- Molecular SPECT Imaging: An OverviewInternational Journal of Molecular Imaging, 2011
- Targeted multi-pinhole SPECTEuropean Journal of Nuclear Medicine and Molecular Imaging, 2010
- Pixel-based subsets for rapid multi-pinhole SPECT reconstructionPhysics in Medicine & Biology, 2010
- Confocal full-field X-ray microscope for novel three-dimensional X-ray imagingJournal of Synchrotron Radiation, 2009
- First experimental result with fluorescent X‐ray CT based on sheet‐beam geometryX-Ray Spectrometry, 2009
- X-ray fluorescent CT imaging of cerebral uptake of stable-iodine perfusion agent iodoamphetamine analog IMP in miceJournal of Synchrotron Radiation, 2008
- Visualization of age-dependent myocardial metabolic impairment in cardiomyopathic model hamster obtained by fluorescent X-ray computed tomography using I-127 BMIPPJournal of Synchrotron Radiation, 2008
- Small animal SPECT and its place in the matrix of molecular imaging technologiesPhysics in Medicine & Biology, 2005
- Reconstruction method for fluorescent X-ray computed tomography by least-squares method using singular value decompositionIEEE Transactions on Nuclear Science, 1997
- Fluorescent Computer Tomography: A Model For Correction Of X-ray AbsorptionIEEE Transactions on Nuclear Science, 1991