Macroprolactin on the Advia Centaur: experience with 409 patients over a three-year period
Authors:
- 22 October 2009
- journal article
- Published by SAGE Publications in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Vol. 46 (6) , 501-504
Abstract
Introduction: Macroprolactin (MPRL) is an important source of interference that may lead to misdiagnosis and mismanagement of hyperprolactinaemic patients. Prolactin assays exhibit considerable variation in the detection of MPRL. In this study, we examine the requirement for polyethylene glycol (PEG) precipitation in the analysis of hyperprolactinaemia detected by the Advia Centaur as it has a relatively low reactivity with MPRL. Methods: Four hundreds and sixty-four hyperprolactinaemic samples were collected from the laboratory information system for Saint James University Hospital over a three-year period. These samples were screened for MPRL using PEG precipitation protocol. Monomeric prolactin concentration post-PEG precipitation was compared with a reference range determined by PEG precipitation in normal subjects. Results: MPRL was the cause of hyperprolactinaemia in 4% of patients (16/409) over the three-year period studied. Nine subjects with MPRL also had elevated monomeric prolactin. Conclusions: PEG screening is still needed for assays with low MPRL reactivity such as the Advia Centaur and this should be performed with a locally derived reference range for monomeric prolactin.Keywords
This publication has 10 references indexed in Scilit:
- Serum Total Prolactin and Monomeric Prolactin Reference Intervals Determined by Precipitation with Polyethylene Glycol: Evaluation and Validation on Common ImmunoAssay PlatformsClinical Chemistry, 2008
- False-positive polyethylene glycol precipitation tests for macroprolactin due to increased serum globulinsAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2008
- Specificity and Clinical Utility of Methods for the Detection of MacroprolactinClinical Chemistry, 2006
- Prostate-specific antigen: bias and molarity of commercial assays for PSA in use in EnglandAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2006
- Macroprolactin(s): composition and reactivity in immunoassays and laboratory interpretation of results of an unusual patient serumAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2006
- Sorting the wheat from the chaff in macroprolactinaemia assessmentAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2006
- Macroprolactin; high molecular mass forms of circulating prolactinAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2005
- Frequent Misdiagnosis and Mismanagement of Hyperprolactinemic Patients before the Introduction of Macroprolactin Screening: Application of a New Strict Laboratory Definition of MacroprolactinemiaClinical Chemistry, 2003
- Macroprolactinaemia: Contribution to Hyperprolactinaemia in a District General Hospital and Evaluation of a Screening Test Based on Precipitation with Polyethylene GlycolAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 1997
- Mechanism of precipitation of proteins by polyethylene glycols. Analysis in terms of excluded volume.Journal of Biological Chemistry, 1981