First-Line Support by Intra-Aortic Balloon Pump in Non-Ischaemic Cardiogenic Shock in the Era of Modern Ventricular Assist Devices
Open Access
- 1 January 2017
- journal article
- research article
- Published by S. Karger AG in Cardiology
- Vol. 138 (1) , 1-8
Abstract
Objectives: Little is known about circulatory support in cardiogenic shock (CS) from other causes than the acute coronary syndrome or after cardiotomy. We evaluated the effects of first-line intra-aortic balloon pump (IABP) support in this subpopulation of CS patients. Methods: A retrospective study was performed in 27 patients with CS from end-stage cardiomyopathy supported firstly by IABP in the years 2011-2016. Results: At 24 h, lactate decreased from 3.2 (2.1-6.8) to 1.8 (1.2-2.2) mmol/L (p < 0.001). Eighteen patients (67%) defined as IABP responders were successfully bridged to either recovery (n = 7), left ventricular assist device (n = 5), or heart transplantation (n = 6). IABP failed in 9 patients (non-responders, 33%) who either died (n = 7) or needed support by extracorporeal membrane oxygenation (n = 2). At 24 h of IABP support, urinary output was higher (2,660 [1,835-4,440] vs. 1,200 [649-2,385] mL; p = 0.02) and fluid balance more negative (-1,564 [-2,673 to -1,086] vs. -500 [-930 to +240] mL; p < 0.001) in responders than non-responders. Overall survival at 1 year was 63%. Conclusion: In most patients, first-line support by IABP in end-stage cardiomyopathy is associated with improvement in organ perfusion and clinical stabilisation for at least 24 h allowing time for decision making on next therapies.Keywords
This publication has 23 references indexed in Scilit:
- Circulatory ShockThe New England journal of medicine, 2013
- Intraaortic Balloon Support for Cardiogenic ShockNew England Journal of Medicine, 2013
- Predicting Survival in Patients Receiving Continuous Flow Left Ventricular Assist DevicesJACC, 2013
- Percutaneous Circulatory Support in Cardiogenic ShockCirculation, 2012
- Acute and critically ill peripartum cardiomyopathy and 'bridge to' therapeutic options: a single center experience with intra-aortic balloon pump, extra corporeal membrane oxygenation and continuous-flow left ventricular assist devicesCritical Care, 2011
- The Percutaneous Ventricular Assist Device in Severe Refractory Cardiogenic ShockJACC, 2011
- Percutaneous left ventricular assist devices vs. intra-aortic balloon pump counterpulsation for treatment of cardiogenic shock: a meta-analysis of controlled trialsEuropean Heart Journal, 2009
- Intra-aortic balloon pumping increases renal blood flow in patients with low left ventricular ejection fractionPerfusion, 2008
- Intra-aortic balloon counterpulsation in decompensated cardiomyopathy patients: bridge to transplantation or assist deviceInteractive CardioVascular and Thoracic Surgery, 2006
- Aortic counterpulsation: A review of the hemodynamic effects and indications for useCatheterization and Cardiovascular Interventions, 2005