Parotid gland radiation dose‐xerostomia relationships based on actual delivered dose for nasopharyngeal carcinoma
Open Access
- 17 April 2018
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 19 (3) , 251-260
Abstract
Xerostomia induced by radiotherapy is a common toxicity for head and neck carcinoma patients. In this study, the deformable image registration of planning computed tomography (CT) and weekly cone‐beam CT (CBCT) was used to override the Hounsfield unit value of CBCT, and the modified CBCT was introduced to estimate the radiation dose delivered during the course of treatment. Herein, the beams from each patient's treatment plan were applied to the modified CBCT to construct the weekly delivered dose. Then, weekly doses were summed together to obtain the accumulated dose. A total of 42 parotid glands (PGs) of 21 nasopharyngeal carcinoma patients were analyzed. Doses delivered to the parotid glands significantly increased compared with the planning doses. V20, V30, V40, Dmean, and D50 increased by 11.3%, 28.6%, 44.4%, 9.5%, and 8.4% respectively. Of the 21 patients included in the study, eight developed xerostomia and the remaining 13 did not. Both planning and delivered PG Dmean for all patients exceeded tolerance (26 Gy). Among the 21 patients, the planning dose and delivered dose of Dmean were 30.6 Gy and 33.6 Gy, respectively, for patients with xerostomia, and 26.3 Gy and 28.0 Gy, respectively, for patients without xerostomia. The D50 of the planning and delivered dose for patients was below tolerance (30 Gy). The results demonstrated that the p‐value of V20, V30, D50, and Dmean difference of the delivery dose between patients with xerostomia and patients without xerostomia was less than 0.05. However, for the planning dose, the significant dosimetric difference between the two groups only existed in D50 and Dmean. Xerostomia is closely related to V20, V30, D50, and Dmean.Keywords
Funding Information
- National Natural Science Foundation of China (61471226)
- Natural Science Foundation of Shandong Province (ZR2017BF005)
This publication has 37 references indexed in Scilit:
- Expected treatment dose construction and adaptive inverse planning optimization: Implementation for offline head and neck cancer adaptive radiotherapyMedical Physics, 2013
- Volume and dosimetric changes and initial clinical experience of a two-step adaptive intensity modulated radiation therapy (IMRT) scheme for head and neck cancerRadiotherapy and Oncology, 2013
- Adaptive radiotherapy for head and neck cancer—Dosimetric results from a prospective clinical trialRadiotherapy and Oncology, 2013
- Anatomical and Dose Changes of Gross Tumour Volume and Parotid Glands for Head and Neck Cancer Patients during Intensity-modulated Radiotherapy: Effect on the Probability of Xerostomia IncidenceClinical Oncology, 2012
- Active contour for noisy image segmentation based on contourlet transformJournal of Electronic Imaging, 2012
- Parotid Gland Function After Radiotherapy: The Combined Michigan and Utrecht ExperienceInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Adaptive Replanning Strategies Accounting for Shrinkage in Head and Neck IMRTInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Radiation‐induced volume changes in parotid and submandibular glands in patients with head and neck cancer receiving postoperative radiotherapy: A longitudinal studyThe Laryngoscope, 2009
- Quality of Life and Survival Outcome for Patients With Nasopharyngeal Carcinoma Receiving Three-Dimensional Conformal Radiotherapy vs. Intensity-Modulated Radiotherapy—A Longitudinal StudyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- Evaluation of on-board kV cone beam CT (CBCT)-based dose calculationPhysics in Medicine & Biology, 2007