Non-intrusive Occupant Localization Using Floor Vibrations in Dispersive Structure
Authors:
Open Access
- 14 November 2016
- conference paper
- Published by Association for Computing Machinery (ACM)
- p. 378-379
Abstract
We introduce a sensing system which leverages footstep-induced structural vibration for occupant localization. Such localization is important for many smart building applications, such as efficient building management, senior/health care, and security. Compared to other sensing approaches, footstep-induced vibration provides a sensing system which is sparse and non-intrusive. The main challenge of achieving high accuracy using such approach is frequency-dependent wave propagation characteristics, such as dispersion, in floor structure. These characteristics result in distortions in the shape of signal. To overcome such distortions, we decompose the vibration signals into different frequency components using wavelet transform and focus on specific components in all the sensors. In a set of experiments in a real structure, our approach results in average localization errors of 0.41 meters, a 4.4X reduction compared to a baseline approach using raw data.Keywords
This publication has 6 references indexed in Scilit:
- Robust Occupant Detection Through Step-Induced Floor Vibration by Incorporating Structural Characteristics2016
- Occupant traffic estimation through structural vibration sensing2016
- Characterizing wave propagation to improve indoor step-level person localization using floor vibration2016
- LoCo2014
- Multilateration localization in the presence of anchor location uncertainties2012
- LOCALE: Collaborative Localization Estimation for Sparse Mobile Sensor Networks2008