Short‐echo, single‐shot, full‐intensity proton magnetic resonance spectroscopy for neurochemical profiling at 4 T: Validation in the cerebellum and brainstem
Open Access
- 30 November 2010
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 65 (4) , 901-910
Abstract
A short echo time (TE = 24 ms) semiadiabatic localization by adiabatic selective refocusing (LASER) sequence was designed and optimized for full‐intensity proton magnetic resonance spectroscopy (1H MRS) at 4 T. The sequence was combined with VAPOR water suppression and three‐dimensional outer volume suppression for improved localization and suppression of unwanted coherences. Artifact‐free, single‐shot spectra were obtained from the human brain with a spectral pattern almost identical to that obtained with an ultra‐short TE (TE = 5 ms) stimulated‐echo acquisition mode (STEAM) sequence as a result of the train of adiabatic refocusing pulses in semi‐LASER that reduce the apparent TE. Approximately 2‐fold higher signal intensity relative to STEAM was demonstrated in phantoms and the human brain. To test the performance of the sequence in clinically relevant brain regions with a volume coil, semi‐LASER spectra were acquired from three cerebellar and brainstem volumes of interest (VOIs) in 23 healthy subjects. Ultra‐short echo STEAM spectra were acquired from the same VOIs to compare neurochemical profiles obtained with semi‐LASER with those obtained with STEAM. Neurochemical profiles of the cerebellum and brainstem acquired by these two techniques were nearly identical, validating the accuracy of the metabolite concentrations obtained with semi‐LASER at the longer TE relative to STEAM. A high correlation between metabolite concentrations obtained by these two proton 1H MRS techniques indicated the sensitivity to detect intersubject variation in metabolite levels. Magn Reson Med, 2010.Keywords
Funding Information
- NINDS (R21 NS056172)
- National Center for Research Resources (P41RR008079)
- NIH (P30NS057091)
- Minnesota Medical Foundation
This publication has 37 references indexed in Scilit:
- Regional neurochemical profiles in the human brain measured by 1H MRS at 7 T using local B1 shimmingNMR in Biomedicine, 2011
- Neurochemical alterations in spinocerebellar ataxia type 1 and their correlations with clinical statusMovement Disorders, 2010
- In vivo 1H NMR spectroscopy of the human brain at high magnetic fields: Metabolite quantification at 4T vs. 7TMagnetic Resonance in Medicine, 2009
- Regional apparent metabolite concentrations in young adult brain measured by 1H MR spectroscopy at 3 TeslaJournal of Magnetic Resonance Imaging, 2008
- Towards 1H-MRSI of the human brain at 7T with slice-selective adiabatic refocusing pulsesMagnetic Resonance Materials in Physics, Biology and Medicine, 2008
- Short echo time 1H‐MRSI of the human brain at 3T with minimal chemical shift displacement errors using adiabatic refocusing pulsesMagnetic Resonance in Medicine, 2007
- Methodology of1H NMR spectroscopy of the human brain at very high magnetic fieldsApplied Magnetic Resonance, 2005
- Proton NMR chemical shifts and coupling constants for brain metabolitesNMR in Biomedicine, 2000
- High frequency volume coils for clinical NMR imaging and spectroscopyMagnetic Resonance in Medicine, 1994
- Estimation of metabolite concentrations from localized in vivo proton NMR spectraMagnetic Resonance in Medicine, 1993