Effects of Flow Rate on Crack Growth in Sensitized Type 304 Stainless Steel in High-Temperature Aqueous Solutions
Authors:
- 1 May 2000
- journal article
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 56 (5) , 482-491
Abstract
Effects of flow rate on intergranular crack growth in sensitized Type 304 stainless steel (UNS S30400) in distilled water containing 15 ppm or 25 ppm (2.59 × 10−4 or 4.31 × 10−4 m) sodium chloride (NaCl) at 250°C were examined using compact tension (CT) specimens under constant loading conditions. On increasing the flow rate, the crack growth rate (CGR) drastically increased, but later decreased to a level that was lower than the initial value. The initial increase in CGR was attributed to an enhanced rate of mass transfer of oxygen to the external surface, where it consumed the current emanating from the crack mouth. However, the subsequent decrease in CGR was attributed to crack flushing, which is a delayed process because of the time required to destroy the aggressive conditions that exist within the crack. Once flushing destroyed the aggressive crack environment, CGR decreased with increasing flow rate. The time over which CGR increased after an increase in the flow rate depended on how fast crack flushing occurred by fluid flow; the higher the flow rate and the greater the crack opening, the faster the crack flushing and the shorter the transition time. Finally, intergranular cracks propagated faster in regions nearer both sides of the CT specimens, where the oxygen supply to the external surface was enhanced under stirring conditions and where minimal resistance existed to current flow from the crack tip to the external surfaces. This observation provided evidence that the crack’s internal and external environments were coupled electrochemically.Keywords
This publication has 13 references indexed in Scilit:
- The effect of dielectric coatings on igscc in sensitized type 304 ss in high temperature dilute sodium sulfate solutionCorrosion Science, 1998
- Flow Rate Dependence of Localized Corrosion in Thermal Power Plant Materials1997
- Theoretical Estimation of Crack Growth Rates in Type 304 Stainless Steel in Boiling-Water Reactor Coolant EnvironmentsCorrosion, 1996
- Determination of the fate of the current in the stress corrosion cracking of sensitized type 304SS in high temperature aqueous systemsCorrosion Science, 1995
- A coupled environment model for stress corrosion cracking in sensitized type 304 stainless steel in LWR environmentsCorrosion Science, 1991
- The Effect of Fluid Flow on the Stress Corrosion Cracking of ASTM A508 Cl 2 Steel and AISI Type 304 Stainless Steel in High Temperature WaterCorrosion, 1982
- Visualization of Separating Stokes FlowsJournal of the Physical Society of Japan, 1979
- External Reference Electrodes for Use in High Temperature Aqueous SystemsJournal of the Electrochemical Society, 1979
- Mechanism of Chloride Stress Corrosion Cracking of Austenitic Stainless SteelsCorrosion, 1969
- Steady flows in rectangular cavitiesJournal of Fluid Mechanics, 1967