Characterisation of microcalcification clusters on 2D digital mammography (FFDM) and digital breast tomosynthesis (DBT): does DBT underestimate microcalcification clusters? Results of a multicentre study
- 29 August 2014
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 25 (1) , 9-14
Abstract
To compare DBT and FFDM in the classification of microcalcification clusters (MCs) using BI-RADS. This Institutional Review Board-approved study was undertaken in three centres. A total of 107 MCs evaluated with both DBT and FFDM were randomised for prospective reading by six experienced breast radiologists and classified using BI-RADS. The benign/malignant ratio of MC was 66/41. Of 11/107 discordant results, DBT classified MCs as R2 whereas FFDM classified them as R3 in 9 and R4 in 2. Three of these (3/107 = 2.8 %) were malignant; 8 (7.5 %) were nonmalignant and were correctly classified as R2 on DBT but incorrectly classified as R3 on FFDM. Estimated sensitivity and specificity, respectively, were 100 % (95 % CI: 91 % to 100 %) and 94.6 % (95 % CI: 86.7 % to 98.5 %) for FFDM and 91.1 % (95 % CI: 78.8 % to 97.5 %) and 100 % (95 % CI: 94.8 % to 100 %) for DBT. Overall intra- and interobserver agreements were 0.75 (95 % CI: 0.61-0.84) and 0.73 (95 % CI: 0.62-0.78). Most MCs are scored similarly on FFDM and DBT. Although a minority (11/107) of MCs are classified differently on FFDM (benign MC classified as R3) and DBT (malignant MC classified as R2), this may have clinical relevance. • The BI-RADS classification of MC differs for FFDM and DBT in 11/107 cases • DBT assigned lower BI-RADS classes compared to FFDM in 11 clusters • In 4/107 DBT may have missed some malignant and high-risk lesions • In 7/107 the ‘underclassification’ on DBT was correct, potentially avoiding unnecessary biopsies • DBT may miss a small proportion of malignant lesionsKeywords
This publication has 12 references indexed in Scilit:
- Flat Epithelial Atypia: Comparison Between 9-Gauge and 11-Gauge DevicesClinical Breast Cancer, 2013
- Diagnostic accuracy of digital breast tomosynthesis versus digital mammography for benign and malignant lesions in breasts: a meta-analysisEuropean Radiology, 2013
- 'In vivo' average glandular dose evaluation: one-to-one comparison between digital breast tomosynthesis and full-field digital mammographyRadiation Protection Dosimetry, 2013
- Integration of 3D digital mammography with tomosynthesis for population breast-cancer screening (STORM): a prospective comparison studyThe Lancet Oncology, 2013
- Comparison of Digital Mammography Alone and Digital Mammography Plus Tomosynthesis in a Population-based Screening ProgramRadiology, 2013
- Assessing Radiologist Performance Using Combined Digital Mammography and Breast Tomosynthesis Compared with Digital Mammography Alone: Results of a Multicenter, Multireader TrialRadiology, 2013
- TOMMY Trial (a comparison of tomosynthesis with digital mammography in the UK NHS breast screening programme) setting up a multicentre imaging trialBreast Cancer Research, 2011
- Calcifications in the Breast and Digital Breast TomosynthesisThe Breast Journal, 2011
- Detection and Classification of Calcifications on Digital Breast Tomosynthesis and 2D Digital Mammography: A ComparisonAmerican Journal of Roentgenology, 2011
- Analysis of interval cancers observed in an Italian mammography screening programme (2000–2006)La radiologia medica, 2009