Practical Immuno-PET Radiotracer Design Considerations for Human Immune Checkpoint Imaging
Open Access
- 15 December 2016
- journal article
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 58 (4) , 538-546
Abstract
Immune checkpoint blockade has emerged as a promising cancer treatment paradigm. Unfortunately, there are still a large number of patients and malignancies that do not respond to therapy. A major barrier to validating biomarkers for the prediction and monitoring of responders to clinical checkpoint blockade has been the lack of imaging tools to accurately assess dynamic immune checkpoint expression. Here, we sought to optimize noninvasive immuno-PET imaging of human programmed death-ligand 1 (PD-L1) expression, in a preclinical model, using a small high-affinity engineered protein scaffold (HAC-PD1). Six HAC-PD1 radiotracer variants were developed and used in preclinical imaging and biodistribution studies to assess their ability to detect human PD-L1 expression in vivo. Radiotracer design modifications included chelate, glycosylation, and radiometal. HACA-PD1 was adopted as the naming convention for aglycosylated tracer variants. NOD scid γ-(NSG) mice were inoculated with subcutaneous tumors engineered to either be constitutively positive (CT26 hPD-L1) or be negative (ΔmPD-L1 CT26) for human PD-L1 expression. When the tumors had grown to an average size of 1 cm in diameter, mice were injected with 0.75–2.25 MBq (∼10 μg) of an engineered radiotracer variant and imaged. At 1 h after injection, organs were harvested for biodistribution. Of the practical immuno-PET tracer modifications considered, glycosylation was the most prominent design factor affecting tracer uptake, specificity, and clearance. In imaging studies, aglycosylated 64Cu-NOTA-HACA-PD1 most accurately visualized human PD-L1 expression in vivo. We reasoned that because of the scaffold’s small size (14 kDa), its pharmacokinetics may be suitable for labeling with the short-lived and widely clinically available radiometal 68Ga. At 1 h after injection, 68Ga-NOTA-HACA-PD1 and 68Ga-DOTA-HACA-PD1 exhibited promising target-to-background ratios in ex vivo biodistribution studies (12.3 and 15.2 tumor-to-muscle ratios, respectively). Notably, all HAC-PD1 radiotracer variants enabled much earlier detection of human PD-L1 expression (1 h after injection) than previously reported radiolabeled antibodies (>24 h after injection). This work provides a template for assessing immuno-PET tracer design parameters and supports the translation of small engineered protein radiotracers for imaging human immune checkpoints.Keywords
This publication has 33 references indexed in Scilit:
- Challenges of phase 1 clinical trials evaluating immune checkpoint-targeted antibodiesAnnals of Oncology, 2016
- Prognostic impact of programmed cell death-1 (PD-1) and PD-ligand 1 (PD-L1) expression in cancer cells and tumor-infiltrating lymphocytes in ovarian high grade serous carcinomaOncotarget, 2015
- Programmed Death-1 Ligand-1 (PDL1) Expression Is Associated with the Prognosis of Patients with Stage II/III Gastric Cancer.2015
- A Threshold Level of Intratumor CD8+ T-cell PD1 Expression Dictates Therapeutic Response to Anti-PD1Cancer Research, 2015
- Programmed cell death ligand 1 (PD-L1) expression on gastric cancer and its relationship with clinicopathologic factors.2015
- Noninvasive Imaging of Tumor PD-L1 Expression Using Radiolabeled Anti–PD-L1 AntibodiesCancer Research, 2015
- Clinical blockade of PD1 and LAG3 — potential mechanisms of actionNature Reviews Immunology, 2014
- Predictive correlates of response to the anti-PD-L1 antibody MPDL3280A in cancer patientsNature, 2014
- Prognostic and predictive markers for the new immunotherapies.2014
- Nivolumab plus Ipilimumab in Advanced MelanomaNew England Journal of Medicine, 2013