Determination of curcumin in bouillon cubes by high-performance thin-layer chromatography
Authors:
- A. V. Bogatsky Physico-Chemical Institute of the National Academy of Sciences of UkraineAUA. V. Bogatsky Physico-Chemical Institute of the National Academy of Sciences of Ukraine
- A YegorovaAYA Yegorova
- Yu LoskutovaYLYu Loskutova
- InterChem SLCISInterChem SLC
- G VoitiukGVG Voitiuk
- A MaltsevAMA Maltsev
- E MalinkaEME Malinka
- Odessa National Academy Of Food TechnologiesOTOdessa National Academy Of Food Technologies
- Yu ScrypynetsYSYu Scrypynets
- 18 February 2021
- journal article
- research article
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Zurnal Hromatograficnogo tovaristva
- Vol. 20 (66) , 4-14
Abstract
Currently, high-performance thin-layer chromatography (HPTLC) is widely used to control product quality in the pharmaceutical and food industries. In the manufacture of food products, the most important requirement is the control of the content of various additives (preservatives, dyes, antioxidants). For the first time, a method for determining curcumin by high-performance thin-layer chromatography in bouillon cubes "Gallina Blanca" was proposed. Detection was carried out by densitometric scanning using CAMAG equipment when measuring absorbance at a wavelength 265 nm. The method is based on determining the peak area of curcumin in the chromatogram depending on its concentration. Curcumin content is determined by the calibration curve. The developed method was validated by the following tests: specificity, linearity, accuracy and detection limit. The calibration curve is linear in the range of curcumin concentrations from 120 to 520 ng/spot, the detection limit is 65 ng/spot. The specificity of the method is based on the ability to unambiguously evaluate the analyte in the presence of other components and is confirmed by using an external standard. The spots on the chromatograms of the test solution and the reference solution coincide in the value of Rf, which confirms the specificity of the method. Accuracy was evaluated according to the results of the analysis of various samples. The requirement for statistical insignificance of systematic error is fulfilled. The proposed method is express, characterized by satisfactory metrological characteristics, ease of implementation. Key words: high-performance thin-layer chromatography, curcumin, validation.Keywords
This publication has 12 references indexed in Scilit:
- A critical review of analytical methods for determination of curcuminoids in turmericJournal of Food Science and Technology, 2019
- A Critical Review of the Properties and Analytical Methods for the Determination of Curcumin in Biological and Pharmaceutical MatricesCritical Reviews in Analytical Chemistry, 2018
- Fluorometric based procedure for measuring curcumin concentration in commercial herbal medicinesOptik, 2017
- Simultaneous quantification of curcuminoids and xanthorrhizol inCurcuma xanthorrhizaby high-performance liquid chromatographyJournal of Liquid Chromatography & Related Technologies, 2017
- A NEW STABILITY-INDICATING RP-HPLC METHOD FOR DETERMINATION OF CURCUMIN: AN APPLICATION TO NANOPARTICULATE FORMULATIONInternational Journal of Pharmacy and Pharmaceutical Sciences, 2016
- Electrochemical Behavior and Voltammetric Determination of Curcumin at Electrochemically Reduced Graphene Oxide Modified Glassy Carbon ElectrodeElectroanalysis, 2015
- Development and validation of UV Spectrophotometric method for the estimation of Curcumin in cream formulationPharmaceutical Methods, 2013
- Voltammetric determination of curcumin in spicesJournal of Analytical Chemistry, 2012
- Development and validation of a fluorimetric method to determine curcumin in lipid and polymeric nanocapsule suspensionsBrazilian Journal of Pharmaceutical Sciences, 2010
- Simple HPLC Method for Resolution of Curcuminoids with Antioxidant PotentialJournal of Food Science, 2009