The Influence of Laser Linewidth on the Brillouin Shift Frequency Accuracy of BOTDR
Open Access
- 25 December 2018
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 9 (1) , 58
Abstract
This paper analyzes the influence of laser linewidth on the measurement accuracy of a frequency-scanning Brillouin optical time domain reflectometer (FS-BOTDR), allowing for both the width of Brillouin gain spectrum and the signal-to-noise ratio (SNR) of the BOTDR system. The measurement accuracy of the Brillouin frequency shift (BFS) is theoretically investigated versus the duration of the probe pulse and the linewidth of the laser source, by numerically simulating how a FS-BOTDR works and evaluating the Brillouin gain spectrum (BGS) width and the system SNR. The simulation results show that the BFS accuracy is improved as the laser linewidth becomes narrower when the probe pulse width is fixed. We utilize five types of lasers with respective linewidths of 1.05 MHz, 101 kHz, 10.2 kHz, 3.1 kHz, and 98 Hz to compare the BFS measurement accuracy over a ~10 km optical sensing fiber. The experimental results demonstrate that the root-mean-square error (RMSE) of BFS decreases with the laser linewidth narrowing from 1.05 MHz to 3.1 kHz, which is in good agreement with the numerical simulation. However, the RMSE of BFS increases when the laser linewidth is less than 3.1 kHz, which may arise from the coherent Rayleigh noise due to a too narrow laser linewidth. The results can provide a theoretical basis and experimental guidance for choosing the appropriate laser linewidth in BOTDR.Keywords
Funding Information
- National Natural Science Foundation of China (61805167)
- The Coal-Bed Methane Joint Research Fund of Shanxi Province, China (2015012005 and 2016012011)
- The Social Development Project of Shanxi Province Key Research Plan, China (201703D321034)
This publication has 32 references indexed in Scilit:
- Recent progress of using Brillouin distributed fiber optic sensors for geotechnical health monitoringSensors and Actuators A: Physical, 2017
- Analysis of Fiber-Optic Strain-Monitoring Data from a Prestressed Concrete BridgeJournal of Bridge Engineering, 2017
- On-line temperature monitoring in power transmission lines based on Brillouin optical time domain reflectometryOptik, 2015
- Determining the Change of Brillouin Frequency Shift by Using the Similarity Matching MethodJournal of Lightwave Technology, 2015
- Estimating tunnel wall displacements using a simple sensor based on a Brillouin optical time domain reflectometer apparatusInternational Journal of Rock Mechanics and Mining Sciences, 2015
- Performance of a Distributed Simultaneous Strain and Temperature Sensor Based on a Fabry-Perot Laser Diode and a Dual-Stage FBG Optical DemultiplexerSensors, 2013
- Reducing Trade-Off Between Spatial Resolution and Frequency Accuracy in BOTDR Using Cohen's Class Signal Processing MethodIEEE Photonics Technology Letters, 2012
- Enhanced Simultaneous Distributed Strain and Temperature Fiber Sensor Employing Spontaneous Brillouin Scattering and Optical Pulse CodingIEEE Photonics Technology Letters, 2009
- Application of a distributed fibre optic strain sensing system to monitoring changes in the state of an underground mineMeasurement Science and Technology, 2007
- Distributed fiber temperature and strain sensor using coherent radio-frequency detection of spontaneous Brillouin scatteringApplied Optics, 2007