Antioxidant Trace Element Reduction in an In Vitro Cardiopulmonary Bypass Circuit
- 1 May 2012
- journal article
- research article
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 58 (3) , 217-222
Abstract
Many complications occurring after cardiac surgery are attributed to an acute increase in reactive oxygen and reactive nitrogen species, which under normal conditions are balanced by the antioxidant response. Two key enzymes of the antioxidant response, glutathione peroxidase (GPx) and superoxide dismutase (SOD), rely on trace elements for normal function. It was hypothesized that circulation of blood through the cardiopulmonary bypass (CPB) circuit would 1) reduce trace element levels and antioxidant function, 2) increase oxidative stress, and that 3) prepriming circuits with albumin would ameliorate trace element loss. This hypothesis was investigated by circulating fresh human whole blood in an in vitro CPB circuit. Plasma selenium, copper, and zinc levels were measured, as were SOD and GPx and oxidative stress by thiobarbituric acid reactive substances (TBARS). In spite of significant decreases in copper and zinc levels, SOD levels increased with time. Significant decreases in selenium were associated with a trend to increase TBARS but no change in GPx. Prepriming with albumin provided no benefit as it did not reduce trace element loss nor alter levels of oxidative stress. This study confirms that CPB circuits cause significant depletion of trace elements (selenium, copper, and zinc) necessary to maintain redox homeostasis. The loss of trace elements is a potential contributor to cardiac surgical morbidities, and further studies in the cardiac patient population are needed to investigate this.Keywords
This publication has 24 references indexed in Scilit:
- The intraoperative decrease of selenium is associated with the postoperative development of multiorgan dysfunction in cardiac surgical patients*Critical Care Medicine, 2011
- The effects of normoxic versus hyperoxic cardiopulmonary bypass on oxidative stress and inflammatory response in cyanotic pediatric patients undergoing open cardiac surgery: A randomized controlled trialThe Journal of Thoracic and Cardiovascular Surgery, 2009
- Interaction of plasma proteins with commercial protein repellent polyvinyl chloride (PVC): a word of cautionPerfusion, 2008
- Alterations of antioxidant trace elements (Zn, Se, Cu) and related metallo-enzymes in plasma and tissues following burn injury in ratsBurns, 2005
- Effect of NADPH oxidase inhibition on cardiopulmonary bypass-induced lung injuryAmerican Journal of Physiology-Heart and Circulatory Physiology, 2004
- Effect of Trillium™ Biopassive Surface coating of the oxygenator on platelet count drop during cardiopulmonary bypassPerfusion, 1999
- Effect of Antioxidant Trace Elements on the Response of Cardiac Tissue to Oxidative StressaAnnals of the New York Academy of Sciences, 1999
- COMPARISON OF PROTEIN ADSORPTION AND PLATELET ADHESION ON THE SURFACE OF OXYGENATOR MEMBRANESASAIO Journal, 1997
- Mechanical White Blood Cell Damage in Rotary Blood PumpsArtificial Organs, 1997
- A Dynamic Method for Setting Roller Pumps Nonocclusively Reduces Hemolysis and Predicts Retrograde FlowASAIO Journal, 1997