Estimation of the Bispectral Index by Anesthesiologists
- 1 May 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 114 (5) , 1093-1101
Abstract
Background: Processed electroencephalographic indices, such as the bispectral index (BIS), are potential adjuncts for assessing anesthetic depth. While BIS® monitors might aid anesthetic management, unprocessed or nonproprietary electroencephalographic data may be a rich source of information for clinicians. We hypothesized that anesthesiologists, after training in electroencephalography interpretation, could estimate the index of a reference BIS as accurately as a second BIS® monitor (twin BIS®) (Covidien Medical, Boulder, CO) when provided with clinical and electroencephalographic data. Methods: Two sets of electrodes connected to two separate BIS® monitors were placed on the foreheads of 10 surgical patients undergoing general anesthesia. Electroencephalographic parameters, vital signs, and end-tidal anesthetic gas concentrations were recorded at prespecified time points, and were provided to two sets of anesthesiologists. Ten anesthesiologists received brief structured training in electroencephalograph interpretation and 10 were untrained. Although electroencephalographic waveforms and open-source processed electroencephalograph metrics were provided from the reference BIS®, both groups were blinded to BIS values and were asked to estimate BIS. Results: The trained anesthesiologists averaged as close to or closer to the reference BIS® compared with the twin BIS® monitor for 34% of their BIS estimates versus 26% for the untrained anesthesiologists. Using linear mixed effects model analysis, there was a statistically significant difference between the trained and untrained anesthesiologists (P = 0.02), but no difference between the twin BIS® monitor and trained anesthesiologists (P = 0.9). Conclusion: With limited electroencephalography training and access to clinical data, anesthesiologists can estimate the BIS almost as well as a second BIS® monitor. These results reinforce the potential utility of training anesthesia practitioners in unprocessed electroencephalogram interpretation.Keywords
This publication has 17 references indexed in Scilit:
- Posttraumatic Stress Disorder in Aware Patients from the B-Aware TrialAnesthesia & Analgesia, 2010
- Protocol for the BAG-RECALL clinical trial: a prospective, multi-center, randomized, controlled trial to determine whether a bispectral index-guided protocol is superior to an anesthesia gas-guided protocol in reducing intraoperative awareness with explicit recall in high risk surgical patientsBMC Anesthesiology, 2009
- Processed electroencephalogram in depth of anesthesia monitoringCurrent Opinion in Anaesthesiology, 2009
- Time delay of electroencephalogram index calculation: analysis of cerebral state, bispectral, and Narcotrend indices using perioperatively recorded electroencephalographic signalsBritish Journal of Anaesthesia, 2009
- Does bilateral bispectral index monitoring (BIS) detect the discrepancy of cerebral reperfusion during carotid endarterectomy?Journal of Clinical Anesthesia, 2009
- Practical Use of the Raw Electroencephalogram Waveform During General Anesthesia: The Art and ScienceAnesthesia & Analgesia, 2009
- Monitoring consciousness: the current status of EEG-based depth of anaesthesia monitorsBest Practice & Research Clinical Anaesthesiology, 2007
- Can anaesthetists be taught to interpret the effects of general anaesthesia on the electroencephalogram? Comparison of performance with the BIS and spectral entropyBritish Journal of Anaesthesia, 2007
- Intrapatient Reproducibility of the BISxp® MonitorAnesthesiology, 2006
- Different Conditions That Could Result in the Bispectral Index Indicating an Incorrect Hypnotic StateAnesthesia & Analgesia, 2005