Using an Instrumented Hammer to Predict the Rupture of Bone Samples Subject to an Osteotomy
Open Access
Abstract
Osteotomies are common procedures in maxillofacial and orthopedic surgery. The surgeons still rely on their proprioception to control the progression of the osteotome. Our group has developed an instrumented hammer that was shown to provide information on the biomechanical properties of the tissue located around the osteotome tip. The objective of this study is to determine if this approach may be used to predict the rupture of a bone sample thanks to an instrumented hammer equipped with a force sensor. For each impact, an indicator τ is extracted from the signal corresponding to the variation of the force as a function of time. A linear by part regression analysis is applied to the curve corresponding to the variation of τ as a function of the distance d between the tip of the osteotome and the end of the sample. The experiments were conducted with plywood and bovine trabecular bone samples. The results show that τ starts increasing when the value of d is lower than 2.6 mm on average, which therefore corresponds to a typical threshold detection distance between the osteotome tip and the sample end. These findings open new paths for the development of this instrumented surgical hammer.Keywords
Funding Information
- Agence Nationale de la Recherche (ANR-21-CE19-0035-03, ANR-21-CE17-0004, 101062467)
- Agence Nationale de la Recherche (ANR-21-CE19-0035-03, ANR-21-CE17-0004, 101062467)
- the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation program (ANR-21-CE19-0035-03, ANR-21-CE17-0004, 101062467)
This publication has 29 references indexed in Scilit:
- Intraoperative Image Guidance in Neurosurgery: Development, Current Indications, and Future TrendsRadiology Research and Practice, 2012
- Anterior osteotomy and percutaneous in situ contouring for correction of rigid posttraumatic T12–L1 malunionEuropean Spine Journal, 2011
- Ultrasonic osteotomy as a new technique in craniomaxillofacial surgeryInternational Journal of Oral and Maxillofacial Surgery, 2007
- Piezosurgery: Basics and PossibilitiesImplant Dentistry, 2006
- Dental implants placement in conjunction with osteotome sinus floor elevation: a 12‐year life‐table analysis from a prospective study on 588 ITI®implantsClinical Oral Implants Research, 2005
- Image-guided navigation in oral and maxillofacial surgeryBritish Journal of Oral and Maxillofacial Surgery, 2005
- Microsurgical robotic system for the deep surgical field: development of a prototype and feasibility studies in animal and cadaveric modelsJournal of Neurosurgery, 2005
- Piezosurgery®: an ultrasound device for cutting bone and its use and limitations in maxillofacial surgeryBritish Journal of Oral and Maxillofacial Surgery, 2004
- Comparison of mechanical properties of human, bovine bone and a new processed bone xenograftBiomaterials, 1993
- Physical and mechanical properties of calf lumbosacral trabecular boneJournal of Biomechanics, 1991