A Robust Synchronization to Enhance the Power Quality of Renewable Energy Systems
Authors:
- Lenos HadjidemetriouLHLenos Hadjidemetriou
- Elias KyriakidesElias Kyriakides
- Frede BlaabjergFrede Blaabjerg
- 2 February 2015
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 62 (8) , 4858-4868
Abstract
The increasing penetration of renewable energy sources (RESs) in the power grid requires high-quality power injection under various grid conditions. The synchronization method, usually a phase-locked loop (PLL) algorithm, is directly affecting the response of the grid-side converter of the RES. This paper proposes a new PLL algorithm that uses an advanced decoupling network implemented in the stationary reference frame with limited requirements for processing time to enable a fast and accurate synchronization even under harmonic distorted voltage and low-voltage grid faults. The robust response of the proposed PLL is validated, and the effect of the proposed synchronization on the performance of the grid-connected renewable energy system is investigated. This investigation proves that the robust, accurate, and dynamic response of the new PLL can enhance the quality of the injected power from the RES and can also enable an appropriate fault-ride-through operation under harmonic distorted voltage and grid faults.Keywords
This publication has 38 references indexed in Scilit:
- A grid side converter current controller for accurate current injection under normal and fault ride through operation2013
- StatCom control at wind farms with fixed-speed induction generators under asymmetrical grid faultsIEEE Transactions on Industrial Electronics, 2012
- Enhanced Decoupled Double Synchronous Reference Frame Current Controller for Unbalanced Grid-Voltage ConditionsIEEE Transactions on Power Electronics, 2012
- Safe current injection strategies for a STATCOM under asymmetrical grid faults2010
- Reactive Power Control for Improving Wind Turbine System Behavior Under Grid FaultsIEEE Transactions on Power Electronics, 2009
- Improved Control of DFIG Systems During Network Unbalance Using PI–R Current RegulatorsIEEE Transactions on Industrial Electronics, 2008
- Control scheme in hybrid synchronous stationary frame for PWM AC/DC converter under generalized unbalanced operating conditionsIEEE Transactions on Industry Applications, 2006
- Stationary frame current regulation of PWM inverters with zero steady-state errorIEEE Transactions on Power Electronics, 2003
- Dual current control scheme for PWM converter under unbalanced input voltage conditionsIEEE Transactions on Industrial Electronics, 1999
- Phase-locked loop techniques. A surveyIEEE Transactions on Industrial Electronics, 1996