Amplatzer patent foramen ovale occluder: safety and efficacy
Authors:
- 18 February 2019
- journal article
- research article
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 16 (3) , 173-182
Abstract
The patent foramen ovale (PFO) is a common anatomical variant in humans (prevalence 25%). Most often asymptomatic, it may engender paradoxically embolic strokes, myocardial infarctions, or visceral or peripheral ischemia. It is causatively related to migraine, positional or exertional hypoxemia with dyspnea, diving incidents, high altitude edema, and sleep apnea. Percutaneous closure of atrial septal defects was first performed in the seventies. A dedicated PFO occluder (Amplatzer PFO Occluder) was first used on 10 September 1997 by Kurt Amplatz and Bernhard Meier. Since, percutaneous PFO closure has evolved into one of the most common and the simplest and safest catheter-based intervention in adult cardiology. Randomized studies have proved its benefit for prevention of recurrent ischemic events (particularly strokes) in patients without competing stroke etiology. There are also supportive clinical data for PFO closure in other situations. Areas covered: The Amplatzer PFO Occluder, the first, most implanted, and best-studied PFO occluder, is reviewed, presenting implantation technique, possible complications, and pertinent scientific data of efficacy and safety. Expert commentary: Percutaneous PFO closure has grown to one of the most common procedures in interventional cardiology. Implantation of the Amplatzer PFO Occluder is simple, safe, and effective.Keywords
Funding Information
- not funded
This publication has 54 references indexed in Scilit:
- Antithrombotic and Thrombolytic Therapy for Valvular DiseaseChest, 2012
- Explantation of Patent Foramen Ovale Closure DevicesJACC: Cardiovascular Interventions, 2011
- PFO and paradoxical embolism producing events other than strokeCatheterization and Cardiovascular Interventions, 2011
- Microemboli may link spreading depression, migraine aura, and patent foramen ovaleAnnals of Neurology, 2009
- Late Results After Percutaneous Closure of Patent Foramen Ovale for Secondary Prevention of Paradoxical Embolism Using the Amplatzer PFO Occluder Without Intraprocedural EchocardiographyJACC: Cardiovascular Interventions, 2009
- PFO closure complications from the AGA registryCatheterization and Cardiovascular Interventions, 2008
- Transseptal puncture for catheter ablation of atrial fibrillation after device closure of patent foramen ovaleCatheterization and Cardiovascular Interventions, 2008
- BioSTAR Evaluation STudy (BEST)Circulation, 2006
- Pacman sign during device closure of the patent foramen ovaleCatheterization and Cardiovascular Interventions, 2003
- Nickel release after implantation of the Amplatzer occluderAmerican Heart Journal, 2003