A Miniaturized Low-Intensity Ultrasound Device for Wearable Medical Therapeutic Applications
- 14 October 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 13 (6) , 1372-1382
Abstract
Low-intensity ultrasound has drawn increasing attention recently as a non-invasive modality for medical therapeutic applications. Current commercially available low-intensity ultrasound devices are bulky and expensive. In this paper, a battery-powered miniaturized device is proposed to generate low-intensity therapeutic ultrasound. The proposed device consists of a custom Application-Specific Integrated Circuit (ASIC), an off-chip digital control block, and a piezoelectric transducer. The ASIC, which integrates a DC-DC boost converter and a transducer driver, is implemented in TSMC's 0.18 μm BCD Gen2 process. Measurement results show that a maximum output voltage of 14 V is achieved by the proposed fully-integrated DC-DC boost converter with a battery supply voltage of 3.7 V. The peak power conversion efficiency is 29% and the output power at the peak power conversion efficiency is 105 mW. The on-chip transducer driver employs a half-bridge circuit with two n-type devices at the output stage. A high-voltage level shifter with low power consumption and short propagation delay is proposed in this paper for the high-performance operation of the half-bridge transducer driver. The piezoelectric transducer is a customized transducer with a resonance frequency of 1.5 MHz. At this frequency, the proposed low-intensity ultrasound device is able to generate continuous-wave ultrasound with a therapeutic power intensity of 32 [Formula: see text]. The proposed low-intensity ultrasound device is low-cost, compact, and light-weight, which enables affordable, and wearable applications.Keywords
Funding Information
- China Scholarship Council
- Alberta Innovates Technology Futures
This publication has 28 references indexed in Scilit:
- Effects of Low‐Intensity Ultrasound on Gramicidin D‐Induced Erythrocyte EdemaJournal of Ultrasound in Medicine, 2014
- Design of fast low‐power floating high‐voltage level‐shiftersElectronics Letters, 2014
- Current Status of Low Intensity Pulsed Ultrasound for Dental PurposesThe Open Dentistry Journal, 2012
- Capacitive micromachined ultrasonic transducers for medical imaging and therapyJournal of Micromechanics and Microengineering, 2011
- Osteogenic differentiation of rat bone marrow stromal cells by various intensities of low-intensity pulsed ultrasoundUltrasonics, 2011
- Nanosecond Delay Floating High Voltage Level Shifters in a 0.35 $\mu$m HV-CMOS TechnologyIEEE Journal of Solid-State Circuits, 2010
- Therapeutic applications of ultrasoundProgress in Biophysics and Molecular Biology, 2007
- Long wave ultrasound may enhance bone regeneration by altering OPG/RANKL ratio in human osteoblast-like cellsBone, 2006
- Piezoelectric ceramics and ultrasonic transducersJournal of Physics E: Scientific Instruments, 1989
- The piezo-electric quartz resonator and its equivalent electrical circuitProceedings of the Physical Society of London, 1925