Abstract
To date, no field study has continuously monitored the deep body core temperatures of industrial workers. A program to continuously measure deep body core temperatures in 36 industrial workers working 10-, 12-, and 12.5-hour day and nightshifts in a hot, deep, underground mine in the Tropics was conducted. No heat illness occurred in these workers during the study. Miniaturized radio-transponders (“pills”) taken orally were used to measure temperature during the transit time in the gastrointestinal tract. Commonly recommended limits for industrial hyperthermia are 38.0°C, or an increase of +1°C. The results showed that miners regularly exceeded these limits in terms of maximum deep body core temperature (average, 38.3°C; standard deviation, 0.4°C), maximum temperature rise (1.4°C, 0.4°C), and maximum heat storage (431 kJ, 163 kJ) without reporting any symptoms of heat illness. A significant component of the observed elevated core temperatures was attributable to the normal circadian rhythm, which was measured at 0.9°C (standard deviation, 0.2°C). Evidence was found that workers “self-pace” when under thermal stress.