TWO TO FIVE YEAR FOLLOW-UP OF THE LPM CERAMIC COATED PROXIMAL INTERPHALANGEAL JOINT ARTHROPLASTY
Author:
- 1 February 2008
- journal article
- research article
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 33 (1) , 38-44
Abstract
This paper presents a retrospective series of 20 LPM semi-constrained ceramic coated cobalt chrome proximal interphalangeal joint arthroplasties performed consecutively in 12 patients for arthritis of the proximal interphalangeal joint by a single surgeon between 2000 and 2004. Eleven were performed for osteoarthritis, four for post-traumatic arthritis and five for rheumatoid arthritis. Although 12 joints had an improvement in pain and an increased functional arc of movement, six joints required revision surgery for implant failure at an average of 19 months, with clinical signs of increasing pain, deteriorating motion and radiological signs of implant loosening and subsidence. This rate of revision is higher than in published series for other PIP joint implants and, therefore, close surveillance of all patients with this prosthesis currently in situ is recommended. Use of the prosthesis has ceased in this unit.Keywords
This publication has 14 references indexed in Scilit:
- Pyrolytic Carbon Proximal Interphalangeal Joint Arthroplasty: Results With Minimum Two-Year Follow-Up EvaluationThe Journal of Hand Surgery, 2007
- Problematic Bone Fixation with Pyrocarbon Implants in Proximal Interphalangeal Joint Replacement: Short-Term ResultsJournal of Hand Surgery (European Volume), 2006
- Long-term assessmentof swanson implant arthroplasty in the proximal interphalangeal joint of the handThe Journal of Hand Surgery, 2004
- Morphological Measurements of the Proximal Interphalangeal JointJournal of Hand Surgery (European Volume), 2004
- Kinematics of the proximal interphalangeal joint of the finger after surface replacementThe Journal of Hand Surgery, 2000
- Proximal interphalangeal joint silicone arthroplasty for posttraumatic arthritisThe Journal of Hand Surgery, 1999
- Further studies into proximal interphalangeal joint dimensions for the design of a surface replacement prosthesis: Medullary cavities and transverse plane shapesProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1997
- Development of a surface replacement arthroplasty for proximal interphalangeal jointsThe Journal of Hand Surgery, 1997
- Long-term results of proximal interphalangeal joint resection arthroplasties with a silicone implantThe Journal of Hand Surgery, 1995
- Proximal Interphalangeal Joint ArthroplastyClinical Orthopaedics and Related Research, 1984