Detection of lung lesions in breath-hold VIBE and free-breathing Spiral VIBE MRI compared to CT
Authors:
Open Access
- 24 November 2021
- journal article
- research article
- Published by Springer Nature in Insights into Imaging
- Vol. 12 (1) , 1-8
Abstract
Background: Detection of pulmonary nodules in MRI requires fast imaging strategies without respiratory motion impairment, such as single-breath-hold Cartesian VIBE. As patients with pulmonary diseases have limited breath-hold capacities, this study investigates the clinical feasibility of non-Cartesian Spiral VIBE under free-breathing compared to CT as the gold standard. Methods: Prospective analysis of 27 oncological patients examined in PET/CT and PET/MR. A novel motion-robust 3D ultrashort-echo-time (UTE) MR sequence was evaluated in comparison with CT and conventional breath-hold MR. CT scans were performed under breath-hold in end-expiratory and end-inspiratory position (CT ex, CT in). MR data was acquired with non-contrast-enhanced breath-hold Cartesian VIBE followed by a free-breathing 3D UTE Spiral VIBE. Impact of respiratory motion on pulmonary evaluation was investigated by two readers in Cartesian VIBE, followed by UTE Spiral VIBE and CT ex and the reference standard of CT in. Diagnostic accuracy was calculated, and visual image quality assessed. Results: Higher detection rate and sensitivity of pulmonary nodules in free-breathing UTE Spiral VIBE in comparison with breath-hold Cartesian VIBE were found for lesions > 10 mm (UTE Spiral VIBE/VIBE/CT ex): 93%/54%/100%; Lesions 5–10 mm: 67%/25%/ 92%; Lesions < 5 mm: 11%/11%/78%. Lobe-based analysis revealed sensitivities and specificities of 64%/96%/41% and 96%/93%/100% for UTE Spiral VIBE/VIBE/CT ex. Conclusion: Free-breathing UTE Spiral VIBE indicates higher sensitivity for detection of pulmonary nodules than breath-hold Cartesian VIBE and is a promising but time-consuming approach. However, sensitivity and specificity of inspiratory CT remain superior in comparison and should be preferred for detection of pulmonary lesions.Keywords
Funding Information
- Universitätsklinikum Tübingen
This publication has 21 references indexed in Scilit:
- Pulmonary Embolism Detection with Three-dimensional Ultrashort Echo Time MR Imaging: Experimental Study in CaninesRadiology, 2016
- Detection of Small Pulmonary Nodules with Ultrashort Echo Time Sequences in Oncology Patients by Using a PET/MR SystemRadiology, 2016
- Evaluation of optimized breath‐hold and free‐breathing 3D ultrashort echo time contrast agent‐free MRI of the human lungJournal of Magnetic Resonance Imaging, 2015
- Pulmonary high‐resolution ultrashort TE MR imaging: Comparison with thin‐section standard‐ and low‐dose computed tomography for the assessment of pulmonary parenchyma diseasesJournal of Magnetic Resonance Imaging, 2015
- Quiet Submillimeter MR Imaging of the Lung Is Feasible with a PETRA Sequence at 1.5 TRadiology, 2015
- Optimized 3D ultrashort echo time pulmonary MRIMagnetic Resonance in Medicine, 2012
- MRI of the lung – state of the artDiagnostic and Interventional Radiology, 2011
- Acquisition‐weighted stack of spirals for fast high‐resolution three‐dimensional ultra‐short echo time MR imagingMagnetic Resonance in Medicine, 2008
- MR imaging of the chest: A practical approach at 1.5TEuropean Journal of Radiology, 2007
- Fast T1- and T2-weighted pulmonary MR-imaging in patients with bronchial carcinomaEuropean Journal of Radiology, 2005