Recent advances in enhancing the sensitivity of electrophoresis and electrochromatography in capillaries and microchips (2006–2008)
- 20 January 2009
- journal article
- review article
- Published by Wiley in Electrophoresis
- Vol. 30 (1) , 230-248
Abstract
Poor sensitivity is still considered to be one of the major limitations of electrophoresis, which is surprising given the power, flexibility and versatility of many of the approaches to on‐line concentration that have developed over the last 20 years. This is still a very active area of interest and this review will cover developments in the field over the last two years since the last review (Electrophoresis 2007, 28, 254–281) through to June 2008. It includes developments in the fields of stacking, covering all methods from field‐amplified sample stacking and large volume sample stacking, through to ITP, dynamic pH junction and sweeping. Attention is also given to on‐line or in‐line extraction methods that have been used for electrophoresis.Keywords
This publication has 165 references indexed in Scilit:
- Sorbent preconcentration procedures coupled to capillary electrophoresis for environmental and biological applicationsAnalytica Chimica Acta, 2008
- Characterization of voltage degradation in dynamic field gradient focusingElectrophoresis, 2008
- Assessing the scalability of dynamic field gradient focusing by linear modelingJournal of Separation Science, 2008
- Differentiation of opium and poppy straw using capillary electrophoresis and pattern recognition techniquesAnalytica Chimica Acta, 2007
- Enhanced pH‐mediated stacking of anions for CE incorporating a dynamic pH junctionElectrophoresis, 2007
- Flow manipulation for sweeping with a cationic surfactant in microchip capillary electrophoresisJournal of Chromatography A, 2007
- Application of CE with novel dynamic coatings and field‐amplified sample injection to the sensitive determination of isomeric benzoic acids in atmospheric aerosols and vehicular emissionElectrophoresis, 2007
- Improving the sensitivity of the determination of ceftiofur by capillary electrophoresis in environmental water samples: In-line solid phase extraction and sample stacking techniquesAnalytica Chimica Acta, 2007
- Direct determination of chlorophenols present in liquid samples by using a supported liquid membrane coupled in-line with capillary electrophoresis equipmentAnalytica Chimica Acta, 2007
- Anion‐selective exhaustive injection‐sweeping microemulsion electrokinetic chromatographyElectrophoresis, 2006