Cadaveric study of ergonomics and performance using a robotic exoscope with a head-mounted display in spine surgery
Open Access
- 10 January 2024
- journal article
- research article
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 18 (1) , 1-6
Abstract
The conventional microscope has the disadvantage of a potentially unergonomic posture for the surgeon, which can affect performance. Monitor-based exoscopes could provide a more ergonomic posture, as already shown in pre-clinical studies. The aim of this study was to test the usability and comfort of a novel head-mounted display (HMD)-based exoscope on spinal surgical approaches in a simulated OR setting. A total of 21 neurosurgeons naïve to the device were participated in this prospective trial. After a standardized training session with the device, participants were asked to perform a single-level thoracolumbar decompression surgery on human cadavers using the exoscope. Subsequently, all participants completed a comfort and safety questionnaire. For the objective evaluation of the performance, all interventions were videotaped and analyzed. Twelve men and nine women with a mean age of 34 (range: 24–57) were participating in the study. Average time for decompression was 15 min (IqR 9.6; 24.2); three participants (14%) terminated the procedure prematurely. In these dropouts, a significantly higher incidence of back/neck pain (p = 0.002 for back, p = 0.046 for neck pain) as well as an increased frequency of HMD readjustments (p = 0.045) and decreased depth perception (p = 0.03) were documented. Overall, the surgeons’ satisfaction with the exoscope was 84% (IqR 75; 100). Using a standardized, pre-interventional training, it is possible for exoscope-naïve surgeons to perform sufficient spinal decompression using the HMD-based exoscope with a high satisfaction. However, inaccurate HMD setup prior to the start of the procedure may lead to discomfort and unsatisfactory results.Keywords
All Related Versions
Funding Information
- University of Innsbruck and Medical University of Innsbruck
This publication has 22 references indexed in Scilit:
- 3D Exoscope System in Neurosurgery—Comparison of a Standard Operating Microscope With a New 3D Exoscope in the Cadaver LabOperative Neurosurgery, 2019
- Preliminary experience with a digital robotic exoscope in cranial and spinal surgery: a review of the Synaptive Modus V systemActa Neurochirurgica, 2019
- The Exoscope in Neurosurgery: An Innovative “Point of View”. A Systematic Review of the Technical, Surgical, and Educational AspectsWorld Neurosurgery, 2019
- Optical Versus Virtual Microscope for Medical Education: A Systematic ReviewAnatomical Sciences Education, 2018
- Vitom-3D for Exoscopic Neurosurgery: Initial Experience in Cranial and Spinal ProceduresWorld Neurosurgery, 2017
- Initial experience with a robotically operated video optical telescopic-microscope in cranial neurosurgery: feasibility, safety, and clinical applicationsNeurosurgical Focus, 2017
- Optimal eye movement strategies: a comparison of neurosurgeons gaze patterns when using a surgical microscopeActa Neurochirurgica, 2017
- Effect of alternative video displays on postures, perceived effort, and performance during microsurgery skill tasksApplied Ergonomics, 2016
- Operating microscopes: past, present, and futureNeurosurgical Focus, 2009
- History of the Operating Microscope: From Magnifying Glass to MicroneurosurgeryNeurosurgery, 1998