Performance of Dedicated Versus Integrated Bipolar Defibrillator Leads with CRT‐Defibrillators: Results from a Prospective Multicenter Study
- 23 January 2009
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 32 (2) , 157-165
Abstract
Right ventricular (RV) anodal stimulation may occur in cardiac resynchronization therapy defibrillators (CRT-D) when left ventricular (LV) pacing is configured between the LV lead and an electrode on the RV defibrillator lead. RV defibrillator leads can have a dedicated proximal pacing ring electrode (dedicated bipolar) or utilize the distal shocking coil as the proximal pacing electrode (integrated bipolar). This study compares the performance of integrated versus dedicated leads with respect to anodal stimulation incidence, sensing, and inappropriate ventricular tachyarrhythmia detection in patients implanted with CRT-D. Two hundred ninety-two patients were randomly assigned to receive dedicated or integrated bipolar RV leads at the time of CRT-D implantation. Patients were followed for 6 months. Patients with dedicated bipolar RV leads exhibited markedly higher rates of anodal stimulation than did patients with integrated leads. The incidence of anodal stimulation was 64% at implant for dedicated bipolar RV leads compared to 1% for integrated bipolar RV leads. The likelihood of anodal stimulation in patients with dedicated leads fell progressively during the 6-month follow-up (51.5%), but always exceeded the incidence of anodal stimulation in patients with integrated leads (5%). Clinically detectable undersensing and oversensing were very unusual and did not differ significantly between lead designs. There were no inappropriate ventricular tachyarrhythmia detections for either lead type. Integrated bipolar RV defibrillator leads had a significantly lower incidence of RV anodal stimulation when compared to dedicated bipolar RV defibrillation leads, with no clinically detectable oversensing or undersensing, and with no inappropriate ventricular tachyarrhythmia detections for either lead type.Keywords
This publication has 13 references indexed in Scilit:
- Anodal Capture in Cardiac Resynchronization Therapy Implications for Device ProgrammingPacing and Clinical Electrophysiology, 2006
- The Effect of Anodal Stimulation on V‐V Timing at Varying V‐V IntervalsPacing and Clinical Electrophysiology, 2005
- The Effect of Cardiac Resynchronization on Morbidity and Mortality in Heart FailureThe New England journal of medicine, 2005
- Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart FailureThe New England journal of medicine, 2005
- Prophylactic Use of an Implantable Cardioverter–Defibrillator after Acute Myocardial InfarctionNew England Journal of Medicine, 2004
- Triple-Site Pacing in Patients with Biventricular Device—Incidence of the Phenomenon and Cardiac Resynchronization BenefitJournal of Interventional Cardiac Electrophysiology, 2004
- mparison of edical therapy, acing d defibrillat in heart failure (COMPANION) trial terminated early; combined biventricular pacemaker-defibrillators reduce all-cause mortality and hospitalizationInternational Journal of Cardiology, 2003
- Cardiac Resynchronization in Chronic Heart FailureThe New England journal of medicine, 2002
- Time Dependence of Unipolar Cathodal and Anodal Strength‐Interval CurvesPacing and Clinical Electrophysiology, 1980
- Vulnerability of the mildly ischemic ventricle to cathodal, anodal, and bipolar stimulation.Circulation Research, 1977