Immobilized Diaphorase Surfaces Observed by Scanning Electrochemical Microscope with Shear Force Based Tip−Substrate Positioning
Authors:
- 3 February 2005
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (6) , 1785-1790
Abstract
Imaging of a coimmobilized diaphorase and albumin surface was investigated by scanning electrochemical microscopy (SECM) with shear force based tip-substrate distance control. A microelectrode tip was attached to a commercially available tuning fork to detect the shear force between the microelectrode tip and the surface. We used the standing approach mode, which repeats an approach and retraction at each data point of the surface to obtain simultaneous current and topographic images. To check the performance of our SECM system, we imaged a platinum-patterned array electrode and a diaphorase/albumin coimmobilized glass surface. Since the system acquires current when the tip is retracted to a desired distance, this mode is useful for a relatively large microelectrode (approximately 10 microm) and for scanning a large area (few hundreds of micrometers). Furthermore, by retracting the tip when the tip moves laterally to the next data point to avoid contact between the tip and sample surface, we successfully imaged the surface without destroying its morphology.Keywords
This publication has 21 references indexed in Scilit:
- Integrating an Ultramicroelectrode in an AFM Cantilever: Combined Technology for Enhanced InformationAnalytical Chemistry, 2001
- Noncontact Electrochemical Imaging with Combined Scanning Electrochemical Atomic Force MicroscopyAnalytical Chemistry, 2001
- Studies of charge transfer at liquid|liquid interfaces and bilayer lipid membranes by scanning electrochemical microscopyJournal of Electroanalytical Chemistry, 2000
- Probing liquid∣liquid interfaces using neutron reflection measurements and scanning electrochemical microscopyJournal of Electroanalytical Chemistry, 2000
- Scanning Electrochemistry Microscopy (SECM) in the Study of Electron Transfer Kinetics at Liquid/Liquid Interfaces: Beyond the Constant Composition ApproximationThe Journal of Physical Chemistry B, 1999
- Localized Avidin/Biotin Derivatization of Glassy Carbon Electrodes Using SECMAnalytical Chemistry, 1998
- Scanning electrochemical microscopy (SECM) of facilitated ion transfer at the liquid|liquid interfaceJournal of Electroanalytical Chemistry, 1997
- Microfabrication of Alkylsilanized Glass Substrate by Electrogenerated Hydroxyl Radical Using Scanning Electrochemical MicroscopyLangmuir, 1997
- Polypyrrole towers grown with the scanning electrochemical microscopeAdvanced Materials, 1996
- Microfabrication and Characterization of Diaphorase-Patterned Surfaces by Scanning Electrochemical MicroscopyAnalytical Chemistry, 1995