Assessment of subcutaneous glucose concentration: validation of the wick technique as a reference for implanted electrochemical sensors in normal and diabetic dogs
Authors:
- 1 December 1987
- journal article
- research article
- Published by Springer Nature in Diabetologia
- Vol. 30 (12) , 940-945
Abstract
Employing saline-impregnated cotton threads, an implanted-wick technique was adopted in dogs to obtain specimen from the subcutaneous interstitial compartment in order to estimate its glucose concentration. By measuring the protein, potassium and haemoglobin contents, the centrifuged wick fluid was shown to contain the interstitial concentration of solutes after an equilibration time of approximately 15 min. In normal and in diabetic animals the steady state subcutaneous glucose concentration was almost identical to the circulating glucose level when ranged between 2 and 25 mmol/l. Slow alterations in the circulating glucose profile such as those which appear during an oral glucose tolerance test are closely mirrored by the respective levels in the wick fluid. Fast alterations, however, show deviations. The wick-based glucose levels are well paralleled by the current of Clark type glucose oxidase sensors implanted at the same site. Since, on the basis of in vitro calibrations the sensor outputs have only indicated apparent tissue glucose concentrations of between 70 and 90% of glycaemia, another reference is needed for calibration. Under steady state conditions, the wick method, and on this basis in routine measurements the blood glucose concentration, may be recommended as a reference of implanted sensors which can otherwise not be calibrated in situ.Keywords
This publication has 29 references indexed in Scilit:
- Calcium dependence of histamine‐induced increases in capillary permeability in isolated perfused rat hindquartersActa Physiologica Scandinavica, 1986
- WEARABLE ARTIFICIAL ENDOCRINE PANCREAS WITH NEEDLE-TYPE GLUCOSE SENSORThe Lancet, 1982
- Erogress Toward a Potentially Implantable, Enzyme-Based Glucose SensorDiabetes Care, 1982
- Implanted Electroenzymatic Glucose SensorsDiabetes Care, 1982
- Implanting the Glucose Enzyme Electrode: Problems, Progress, and Alternative SolutionsDiabetes Care, 1982
- Glucose Concentration at Possible Sensor Tissue Implant SitesDiabetes Care, 1982
- Glucose Sensor Characteristics for Miniaturized Portable Closed-Loop Insulin Delivery: A Step Toward ImplantationDiabetes Care, 1982
- Colloid osmotic pressure of human subcutaneous interstitial fluid sampled by nylon wicks: Evaluation of the methodScandinavian Journal of Clinical and Laboratory Investigation, 1982
- Measurement of Colloid Osmotic Pressure of Interstitial FluidActa Physiologica Scandinavica, 1974
- Diffusion of Glucose, Insulin, Inulin, and Evans Blue Protein into Thoracic Duct Lymph of Man*Journal of Clinical Investigation, 1967