Cuff-less blood pressure estimation from photoplethysmography signal and electrocardiogram
Authors:
- 18 March 2021
- journal article
- research article
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 44 (2) , 397-408
Abstract
In recent studies, the physiological parameters derived from human vital signals are found as the status response of the heart and arteries. In this paper, we therefore firstly attempt to extract abundant vital features from photoplethysmography(PPG) signal, its multivariate derivative signals and Electrocardiogram(ECG) signal, which are verified its statistical significance in BP estimation through statistical analysis t-test. Afterwards, the optimal feature set are obtained by usnig mutual information coefficient analysis, which could investigate the potential associations with blood pressure. The optimized feature set are aid as an input to various machine learning strategies for BP estimation. The results indicates that AdaBoost based BP estimation model outperforms other regression methods. Concurrently, AdaBoost-based model is further analyzed by using the Histograms of Estimation Error and Bland–Altman Plot. The results also indicate the great BP estimation performance of the proposed BP estimation method, and it stays within the Advancement of Medical Instrumention(AAMI) standard. Regarding the British Hypertension Society (BHS), it achieves the grade A for DBP and grade B for MAP. Besides, the experimental result illustrated that our proposed BP estimation method could reduce the MAE and the STD, and improve the r for SBP, MAP and DBP estimation, respectively, which further demonstrates the feasibility of our proposed BP estimation method in this paper.Keywords
Funding Information
- Guangzhou Science and Technology Project (201904010107)
- Guangdong Provincial Natural Science Foundation of China (2019A1515010793)
- National Natural Science Foundation of China (61072028)
- Guangdong Province Science and Technology Project (2016B090918071)
This publication has 27 references indexed in Scilit:
- A Neural Network-based method for continuous blood pressure estimation from a PPG signal2013
- Supervised machine learning algorithms for protein structure classificationComputational Biology and Chemistry, 2009
- Using The Morphology of Photoplethysmogram Peaks to Detect Changes in PostureJournal of Clinical Monitoring and Computing, 2006
- One hundred years of auscultatory blood pressureJournal Of Hypertension, 2005
- Continuous and noninvasive estimation of arterial blood pressure using a photoplethysmographic approach2004
- Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood PressureHypertension, 2003
- PhysioBank, PhysioToolkit, and PhysioNetCirculation, 2000
- Personal View: A Centenary of Clinical Blood Pressure Measurement: A Tribute to Scipione Riva-RocciBlood Pressure, 1996
- Borel partitions of infinite subtrees of a perfect treeAnnals of Pure and Applied Logic, 1993
- The British Hypertension Society protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systemsJournal Of Hypertension, 1990