Navigator flip angle optimization for free‐breathing T1‐weighted hepatobiliary phase imaging with gadoxetic acid
- 8 November 2013
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 40 (5) , 1129-1136
Abstract
Purpose To characterize and optimize the navigator‐flip angle (FA), and the influence of imaging‐FA on optimizing liver/lung contrast of the navigator profile, while avoiding visible navigator saturation artifacts, for hepatobiliary phase gadoxetic acid‐enhanced MRI. Materials and Methods Ten volunteers; six men, four women; ages 37.1 ± 11.0 years underwent navigator‐gated three‐dimensional (3D) ‐spoiled‐gradient‐echo sequences in randomized combinations of imaging‐FA (10°/30°) and navigator‐FA (10‐90°) before contrast and 20 min after injection of gadoxetic acid at 3 Tesla. The signal intensities of the liver and lung were measured from navigator profiles. Furthermore, the intensity of saturation artifacts for each navigator FA was quantified using measurements of relative contrast at the artifact location. Results For the postcontrast images, the optimal navigator FA was 90°. However, saturation artifacts were highly dependent on the imaging‐FA and the presence of gadolinium contrast. A smaller imaging‐FA of 10° led to greater saturation artifacts for both pre‐ and postcontrast, and saturation artifacts worsen with increasing navigator‐FA. Using a higher imaging‐FA of 30°, saturation artifacts are ignorable over the entire range of navigator‐FA. Conclusion For navigator‐gated gadoxetic acid‐enhanced hepatobiliary imaging, navigator‐FA of 90° and imaging‐FA of 30° provide an optimal balance with maximum navigator liver/lung contrast while avoiding visible imaging saturation artifacts.J. Magn. Reson. Imaging 2013.Keywords
This publication has 28 references indexed in Scilit:
- Optimized high‐resolution contrast‐enhanced hepatobiliary imaging at 3 tesla: A cross‐over comparison of gadobenate dimeglumine and gadoxetic acidJournal of Magnetic Resonance Imaging, 2011
- Gadoxetic acid disodium‐enhanced magnetic resonance imaging for biliary and vascular evaluations in preoperative living liver donors: Comparison with gadobenate dimeglumine‐enhanced MRIJournal of Magnetic Resonance Imaging, 2010
- Improved Characterization of Focal Liver Lesions With Liver-Specific Gadoxetic Acid Disodium-Enhanced Magnetic Resonance ImagingJournal of Computer Assisted Tomography, 2010
- Detection and Characterization of Focal Liver LesionsInvestigative Radiology, 2010
- Navigated abdominal T1-W MRI permits free-breathing image acquisition with less motion artifactPediatric Radiology, 2010
- Comparison of reconstruction accuracy and efficiency among autocalibrating data‐driven parallel imaging methodsMagnetic Resonance in Medicine, 2008
- Liver Tumor CharacterizationJournal of Computer Assisted Tomography, 2006
- Magnetic resonance imaging of the upper abdomen using a free‐breathing T2‐weighted turbo spin echo sequence with navigator triggered prospective acquisition correctionJournal of Magnetic Resonance Imaging, 2005
- VIBE mit paralleler Akquisitionstechnik - eine neue Möglichkeit der dynamischen kontrastverstärkten MRT der LeberRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2002
- Rapid radiofrequency calibration in MRIMagnetic Resonance in Medicine, 1990