New Convection Correlations for Cooled Ceiling Panels in Room with Mixed and Stratified Airflow
Authors:
- Brendon J. BurleyBBBrendon J. Burley
- 1 April 2006
- journal article
- research article
- Published by Taylor & Francis in HVAC&R Research
- Vol. 12 (2) , 279-294
Abstract
Models for buildings' surface convective boundary conditions are important components of building design and simulation programs. This is especially true for cooled ceiling (CC) panels, which extract major cooling loads from rooms. This paper introduces new convection correlations for rooms with CC panels, developed from laboratory measurements conducted in a full-scale experimental facility. The new convection correlations were developed for CC panels used with or without a ventilation system. When the ventilation system was used, the air was supplied through a high aspiration diffuser. High aspiration diffusers, recommended for use with CC systems, create a specific airflow pattern characterized by narrow and directional jets with a large entrainment of surrounding air. To account for the forced airflow and local buoyancy effects, new convection correlations for CC surfaces were developed as functions of temperature difference and normalized volume flow rate, i.e., the number of air changes per hour (ACH) in the room. Results show that the high aspiration diffuser, even though installed at the ceiling, produces enough air motion in the vicinity of the floor and vertical wall surfaces to affect the convective heat transfer at these surfaces as well. In fact, the effect of forced convection due to the presence of a high aspiration diffuser increases the total convection coefficient at CC surfaces by 4% to 17%.Keywords
This publication has 7 references indexed in Scilit:
- Development of new and validation of existing convection correlations for rooms with displacement ventilation systemsEnergy and Buildings, 2006
- A critical review on the performance and design of combined cooled ceiling and displacement ventilation systemsEnergy and Buildings, 2002
- Mixed convection from heated room surfacesEnergy and Buildings, 2000
- Natural convection from heated room surfacesEnergy and Buildings, 1999
- Validation of heat transfer coefficients on interior building surfaces using a real-sized indoor test cellInternational Journal of Heat and Mass Transfer, 1990
- Improved data correlations for buoyancy-driven convection in roomsBuilding Services Engineering Research & Technology, 1983
- A general expression for the correlation of rates of transfer and other phenomenaAIChE Journal, 1972