This three-dimensional (3D) finite element analysis observed the stress distribution on the prosthetic screws on external hexagon implant and morse taper implant with different tightening loads. For this, two different 3D models assembly were obtained from the manufacturer and transferred to finite element analysis software: External hex implant model (EHM), and Morse taper implant model (MTM), both compounds by 3.75 × 7 mm implant, abutment and abutment screw. Bolt pretension force was applied on the shaft next to the threads of the prosthetic abutment. Preload was calculated using the torque on the prosthetic screw as recommended by the manufacturer (EHM30 and MTM20) and 10 Ncm torque above the manufacturer recommendations (EHM40 and MTM30). Maximum von mises equivalent stresses were obtained on the screws. Preload values results were 243.18N (EHM30), 229.71N (MTM20), 324.24N (EHM40) and 344.57N (MTM30). In EHM30, EHM40 and MTM20 models the maximum stresses were below the yield strength of the abutment screw material. However, the maximum stress in MTM30 model was higher than the reference value. The torque loads above the manufacturer recommendations can cause plastic deformation in the MT abutment screw threads. The screws of morse taper implant can be more sensitive to higher loads than external hexagon implant. The adequate torque can result in screw loosening, while fracture may occur if torque is excessive. Abutment screw suffers many screwing cycles in its lifetime in a way that some tightening forces are above manufacturer recommendations.Keywords
This publication has 29 references indexed in Scilit:
- Stress Evaluation of Implant-Abutment Connections Under Different Loading Conditions: A 3D Finite Element StudyJournal of Oral Implantology, 2015
- Clinical and radiographic evaluation of narrow‐ vs. regular‐diameter dental implants: a 3‐year follow‐up. A retrospective studyClinical Oral Implants Research, 2013
- Consensus report ‐ reconstructions on implants. The Third EAO Consensus Conference 2012Clinical Oral Implants Research, 2012
- Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow‐up of 5 yearsClinical Oral Implants Research, 2012
- Biomechanical evaluation of internal and external hexagon platform switched implant-abutment connections: An in vitro laboratory and three-dimensional finite element analysisDental Materials, 2012
- Effect of repeated screw joint closing and opening cycles on implant prosthetic screw reverse torque and implant and screw thread morphologyThe Journal of Prosthetic Dentistry, 2011
- Comparison of survival and complication rates of tooth‐supported fixed dental prostheses (FDPs) and implant‐supported FDPs and single crowns (SCs)Clinical Oral Implants Research, 2007
- Influence of implant/abutment joint designs on abutment screw loosening in a dental implant systemJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2005
- Finite element analysis to determine implant preloadThe Journal of Prosthetic Dentistry, 2003
- Complications with osseointegrated implantsThe Journal of Prosthetic Dentistry, 1989