Auto‐SENSE perfusion imaging of the whole human heart
Authors:
Open Access
- 18 November 2003
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 18 (6) , 702-708
Abstract
Purpose: To show the application of auto‐sensitivity encoding (SENSE)—a self‐calibrating parallel imaging technique—to first pass perfusion imaging of the whole human heart.Materials and Methods: The self‐calibrating parallel imaging method auto‐SENSE was implemented for a saturation recovery turbo‐fast low‐angle shot (FLASH) sequence on a 1.5‐T scanner using a standard four‐element body phased array coil. By reducing the acquisition time per slice by a factor of two compared to conventional turbo FLASH imaging, the number of imaged slices could be doubled to six to ten with an unchanged temporal resolution of one image per heartbeat. This technique has been tested in eight healthy volunteers for contrast‐enhanced heart perfusion imaging.Results: Auto‐SENSE heart perfusion imaging with improved coverage of the human heart could be performed successfully in all volunteers. A first quantitative comparison of perfusion values between the auto‐SENSE and the non‐SENSE techniques shows good agreement.Conclusion: Auto‐SENSE allows perfusion imaging of the whole human heart without gaps. J. Magn. Reson. Imaging 2003;18:702–708.Keywords
This publication has 21 references indexed in Scilit:
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- Self‐calibrating parallel imaging with automatic coil sensitivity extractionMagnetic Resonance in Medicine, 2002
- VD‐AUTO‐SMASH imagingMagnetic Resonance in Medicine, 2001
- Adaptive sensitivity encoding incorporating temporal filtering (TSENSE)†Magnetic Resonance in Medicine, 2001
- Sensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP)Magnetic Resonance in Medicine, 2000
- Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRIMagnetic Resonance in Medicine, 1999
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- AUTO-SMASH: A self-calibrating technique for SMASH imagingMagnetic Resonance Materials in Physics, Biology and Medicine, 1998
- Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arraysMagnetic Resonance in Medicine, 1997
- First-pass cardiac perfusion: evaluation with ultrafast MR imaging.Radiology, 1990