Determination of Disulfide Bonds in Highly Bridged Disulfide-Linked Peptides by Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry with Postsource Decay
- 1 January 1998
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 70 (1) , 136-143
Abstract
Matrix-assisted laser desorption/ionization mass spectrometry with postsource decay was used to generate fragment ions from peptide fragments containing heteropeptides linked together by two disulfide bonds. Postsource decay analysis of these peptide samples generates a series of singly charged fragment ions that, in addition to the peptide sequence ions, provide useful information for assigning disulfide arrangement in highly bridged disulfide-linked peptides. The assignment was made possible by fragmentation at peptide bonds between two Cys residues in a peptide that constitutes the highly bridged fragment, while retaining the disulfide linkage to the other peptide. Fragmentation using other types of instruments, such as quadrupole ion-trap mass spectrometry with collision-induced dissociation, usually did not generate such fragment ions. The data obtained from postsource decay also provide fragment ions derived from both symmetric and nonsymmetric cleavages of disulfide bonds. The present method is a highly sensitive technique which requires no further sample handling and should be complementary to other classical chemical methods. The method proved useful in facilitating the assignment of disulfide structure in tumor necrosis factor binding protein (TNFbp), which contains 162 amino acids and 13 disulfide bonds (Jones, M.; et al. Biochemistry, in press). Postsource decay analysis of large disulfide-containing peptides usually produces no fragmentation but generates a series of high-intensity ions derived from both symmetric and nonsymmetric cleavages of disulfide bonds.Keywords
This publication has 8 references indexed in Scilit:
- The Quadrupole Ion Trap Mass Spectrometer—A Small Solution to a Big ChallengeAnalytical Biochemistry, 1997
- Post-source Decay and Delayed Extraction in Matrix-assisted Laser Desorption/Ionization-Reflectron Time-of-Flight Mass Spectrometry. Are There Trade-offs?Rapid Communications in Mass Spectrometry, 1996
- Direct assignment of disulfide bonds by Edman degradation of selected peptide fragmentsInternational Journal of Peptide and Protein Research, 1994
- Measurement of equilibrium constants for the formation of esters from aliphatic carboxylic acids and alcoholsAnalytical Chemistry, 1994
- Mass spectrometric sequencing of linear peptides by product‐ion analysis in a reflectron time‐of‐flight mass spectrometer using matrix‐assisted laser desorption ionizationRapid Communications in Mass Spectrometry, 1993
- The disulfide bond pairing of the pheromones Er‐1 and Er‐2 of the ciliated protozoan Euplotes raikoviProtein Science, 1992
- Disulphide bonds and protein stabilityBioEssays, 1988
- Assignment of disulfide bonds in proteins by fast atom bombardment mass spectrometry.Journal of Biological Chemistry, 1987